SPECIAL FUNCTIONS

User Screens
The Kestrel Meter has three User Screens that can be customized to display three current
measurements simultaneously. These screens can also be turned off. (See the Main Menu
section for setup instructions.)
Max/Avg for Wind Speed & Wind Chill
The Max/Avg values for the wind speed and wind chill values are measured independently from the stored
and charted data.
This allows the user to start and stop the averaging period in the most appropriate manner for their
application. Averaging on all wind-related values (Wind Speed and Wind Chill) will be started and
stopped together.
While viewing the Min/Max/Avg screen for any of these measurements, hold the unit into the wind, and
press the
button when the screen displays "--average" to begin collecting data for all measurements, and
again when the screen displays "--stop" to stop collecting data and hold the values on the display. Press the
button when the screen displays "--clear" to clear the data. This routine will work simultaneously for all
measurements, regardless of which one is displayed while the routine is run. The Max/Avg for these wind
values will not affect any other Min/Max/Avg or stored data.
Manual Data Storage
To manually store data, press the
captured and will appear on chart), Full (Overwrite is off and data log is full), or Off (Manual Store button
has been disabled). (See the Main Setup Menu section for more information on memory.)
Tracker
®
button. One of the following will appear: Data Stored (data has been