Slide 45
Water flow through dispenser during Rinse 2 fill
HOT
WATER
V #4
Path #3
Path #4
MIDTERM
DRAIN
SPIN
COLD WATER
V #3
V #1
V #2
Path #2
Path #1
RINSE 2
FILL /
RINSE
Rotation of
Spinner
From no water level (Reset Level) to
Valves #1 & #2 open at the same time. Cold Water from
valves #1 & #2 collides and fills Main wash/Softener/Bleach
compartments.
Valve #1 & #2 are opened for 1
15 seconds, After that, they are opened again to 1
water level.
From 1
st
sensing level to specified water level for each cycle
In order to meet the ATC temperature specification, the Hot
water valve & Cold water valve #1 are opened as needed.
Finally, in order to remove the remaining water in Bleach tray,
Cold water valve #2 is opened for 8 seconds.
1
st
Water Sensing Level
• Wrinkle Control & Quick Wash – 24.9 kHz
• Others – 25.1 kHz
21
DISENTANGLE
SUB
/ FILLING TO
TOTAL
REMOVE SUDS
st
1
sensing level
st
9 seconds and closed for
(25.1kHz),
st
sensing