6.15 ANTI CONDENSATION CONTROL SWITCH (OPTIONAL)

This appliance has the option to go from an electronic intermittent
pilot ignition to a standing pilot for cold climates.

6.16 TIMED BLOWER

Your remote system may have a built in timer (in thermostat mode) that enables the blower to cycle on and
off automatically when the burner turns on and off. With the remote control fan speed preset at the preferred
speed, the blower will come on approximately 5 minutes after the main burner comes on and will shut off
approximately 12 minutes after the burner shuts off.
This time delay is designed to maximize the blower distribution of heated air.
If at any time the burner re-ignites before the twelve minutes are over, the fan will continue to run.
NOTE: At any time in the sequence, the blower can be manually turned on/off using the remote
control.
W415-1035 / A / 10.21.11
RIGHT SIDE OF
DOOR FRAME
(OPERATING SIDE)
ANTI CONDENSATION
CONTROL SWITCH
35.19A