To configure the embedded parameters on a VDU, edit the fields as follows:
IP Address: The IP Address of the AVC Server.
Port Number: The port number of the AVC Server (preset to 1976).
Frame Rate: Offers a means to reduce the quality of a video clip, in order to
ensure that the video clip can still be transmitted without error over a limited
bandwidth network.
 High: all video frames are sent over the network (default value and recommended for
all LANs).
 Medium: every second video frame is sent over the network (recommended for WANs
with more than 1Mb bandwidth).
 Low: every third video frame is sent over the network (recommended for WANs with
less than 1Mb bandwidth).
Disable: A check in this box stops storing video on the AVC Server.
Click the Save button to apply any new settings.
5.2.4.2. I
NTERFACE
Select the interface type. Select either the Default or the Milestone interface type.
5.2.4.2.1. M
ETADATA
A Metadata application running on the device can be configured (optionally) to
send metadata to a specific IP address where another Metadata application (acting
as a client or server) resides, receiving messages from the VDU using XML over
TCP/IP. The server application is responsible for connection handling and
monitoring. The Multi Metadata channel configuration allows you to configure
and enable multiple metadata IP Addresses
To configure the device's embedded parameters that are needed to send
information to multiple Metadata applications, edit the fields as follows:
Enabled: A check in this box enables sending updates to the Metadata
applications.
IP Address: The IP Address of the Metadata applications.
Port Number: The port number of the Metadata applications.
 For Trigger set to 1979.
 For iSense set to 1977.
Device Will Act As a: Select whether the device will act as a Server or Client
(if the other application is set as the Server).
Enable Receiving Metadata: A check in this box enables receiving updates
from the Metadata application (for dependency use).
Receiving Port Number: The port number to receive the Metadata from.
Click the Save button to apply any new settings (for dependency use).