7. Refrigeration Cycle and Cool Air Circulation Route
7-1) Refrigerant Route in Refrigeration cycle
Compressor → Sub-condenser → Side Cluster Pipe(FRE) → Side Cluster Pipe(REF) → Hot Pipe
→ Dryer → Capillary Tube → Refrigerator Evaporator → Freezer Evaporator→ Suction Pipe → Compressor
Refrigerator Evaporator
SIDE CLUSTER PIPE
ACCUMULATOR
Freezer Evaporator
Dryer
Hot Pipe
SUCTION PIPE
SUB-CONDENSER
Capillary Tube
Muffler
Compressor
Hot Pipe
11