Installation

This appliance must be installed in accordance with the relevant elec-
trical wiring rules and regulations. The heater must not be located
immediately below a socket-outlet. A suitable disconnection device
(acting in all active supplies) is required to be incorporated in the fixed
supply wiring. When used in a bathroom, the heater must be installed
such that the controls cannot be touched by a person in the bath or
shower.
Due to the precision of the heater's electronic thermostat, the unit is
highly sensitive to air drafts. For this reason, carefully determine the
unit's location before installation.
The minimum required distance from the heater to any floor is 150mm.
The minimum required distance from the heater to any adjacent wall is
200mm (see figure 3 on page 9).
Important!
When operated for the first time, the heater may emit a
small amount of smoke. This is normal, and should clear
within a few minutes. It is recommended you open
windows and doors during this process.

Connection Details

The heater is supplied with a 1.8m 2-core flex and plug, enabling the
heater to be plugged directly into a socket outlet.
NOTE: This double insulated (Class II) appliance does NOT require
Earthing.
TACTIC.ET10, ET15 and ET20
SKOPE Airelec Convection Panel Heaters
7