Door Locking Motor; Micro Switch (Normally Open Type); Lvt - LG LSE3092ST Service Manual

30” freestanding electric range
Hide thumbs Also See for LSE3092ST:
Table of Contents

Advertisement

Components

Door locking Motor

Micro Switch
(normally open type)

LVT

Test procedures
1. Refer to page 3-14 for the servicing procedure
2. Measure the resistance
(Multiple meter scale: R x 1000)
1. Refer to page 3-14 for the servicing procedure
2. Measure the resistance
(Multiple meter scale: R x 1000)
NO
COM
NOTE: After checking for the continuity of switch, make sure that they are
connected correctly
1. Refer to page 3-3 for the servicing procedure
2. Measure the resistance
(Multiple meter scale: R x 1000)
4-2
Results
Normal: Approximately
2.6 kΩ ± 10%
If not replace
Abnormal: Infinite(open)
below 5Ω (shorted)
Door latch
Door latch
open
Locked
Continuity
Infinite
Normal: Approximately
27 Ω ± 10%
If not replace

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents