Venting Requirements - KitchenAid W10029780 Installation Instructions And Use & Care Manual

30" (76.2 cm) and 36" (91.4 cm) wall-mount canopy range hood
Table of Contents

Advertisement

Available languages

Available languages

Non-vented (recirculating) Installations
For non-vented (recirculating) installations, optional Recirculating
Chimney Kit Part Number 8212713 (Stainless Steel), 8212714
(White), or 8212715 (Black) must be used. These kits include a
new lower chimney cover (that replaces the lower chimney cover
shipped with the range hood), vent grids, a charcoal filter and a
diverter.
10 " (27 cm)
12" (30.5 cm)
(12.7 cm)
30" (76.2 cm)
36" (91.4 cm)
Installation Dimensions
30" (76.2 cm) or 36" (91.4 cm)
cabinet opening width
(if installed between cabinets)
18" (45.7 cm) min.
clearance upper
cabinet to countertop
36" (91.4 cm)
countertop height
Min 32" (81.3 cm)
Max 38 " (96.8 cm)
5"
3 "
(8.9 cm)
22"
(55.9 cm)
12 "
(31.8 cm)
1 "
(3.2 cm)
3
(10 cm)
22" (55.9 cm)
See Note*
X*
*NOTE: The range hood chimneys are adjustable and designed
to meet varying ceiling or soffit heights depending on the
distance "X" between the bottom of the range hood and the
cooking surface. For higher ceilings, a 40" (101.6 cm) Chimney
Extension Kit Part Number 8212710 (Stainless Steel), 8212711
(White), or 8212712 (black) is available from your dealer or an
authorized parts distributor. The chimney extension replaces the
upper chimney shipped with the range hood.
IMPORTANT:
Minimum distance "X": 24" (61.0 cm)
Suggested maximum distance "X": 30" (76.2 cm)
For vented installations, the chimneys can be adjusted for
ceilings between 7' 6 " (2.30 m) and 9' 0" (2.74 m).
For non-vented (recirculating) installations, the chimneys can be
adjusted for ceilings between 8' 3 " (2.45 m) and 9' 5 " (2.88 m).
Vent system must terminate to the outdoors, except for non-
vented (recirculating) installations.
"
Do not terminate the vent system in an attic or other enclosed
area.
Do not use 4" (10.2 cm) laundry-type wall caps.
Use metal vent only. Rigid metal vent is recommended.
Plastic or metal foil vent is not recommended.
The length of vent system and number of elbows should be
kept to a minimum to provide efficient performance.
For the most efficient and quiet operation:
Use no more than three 90° elbows.
Make sure there is a minimum of 24" (61.0 cm) of straight
vent between the elbows if more than 1 elbow is used.
Do not install 2 elbows together.
Use clamps to seal all joints in the vent system.
The vent system must have a damper. If the roof or wall cap
has a damper, do not use the damper supplied with the range
hood.
Use caulking to seal exterior wall or roof opening around the
cap.
The size of the vent should be uniform.
Cold weather installations
An additional back draft damper should be installed to minimize
backward cold air flow and a thermal break should be installed to
minimize conduction of outside temperatures as part of the vent
system. The damper should be on the cold air side of the thermal
break.
The break should be as close as possible to where the vent
system enters the heated portion of the house.
Makeup air
Local building codes may require the use of make up air systems
when using ventilation systems greater than specified CFM of air
movement. The specified CFM varies from locale to locale.
Consult your HVAC professional for specific requirements in your
area.

Venting Requirements

(Vented Models Only)
5