Mini-Specs/Nomenclature; Specifications; Nominal Cooling Capacity; Unit Type - GE Zoneline Data Manual

Vertical packaged terminal air conditioners
Hide thumbs Also See for Zoneline:
Table of Contents

Advertisement

Specifications

230/208 Volt Models
AZ85E09DAC AZ85E12DAC AZ85E18DAC AZ85H09DAC AZ85H12DAC AZ85H18DAC AZ85W09DAC AZ85W12DAC AZ85W18DAC
Features
BTUH
9,000/8,800
E.E.R. (BTUH/Watt)
10.5/10.5
Dehumidification (pints/hr.)
2.5
Universal Heater (kW
@ 230 volts)
2.61/3.42/4.81 2.61/3.42/4.81 2.61/3.42/4.81 2.61/3.42/4.81 2.61/3.42/4.81 2.61/3.42/4.81
Reverse cycle (BTUH)
N/A
COP @ 47°
N/A
SHR
0.81
Indoor CFM (Hi/Med/Low)
0.0" ESP
520/460/360
265 Volt Models
AZ85E09EAC AZ85E12EAC AZ85E18EAC AZ85H09EAC AZ85H12EAC AZ85H18EAC
Features
BTUH
9,000
E.E.R.
10.5
Dehumidification (pints/hr.)
2.5
Universal Heater (kW)
2.71/3.55/5.03 2.71/3.55/5.03 2.71/3.55/5.03 2.71/3.55/5.03 2.71/3.55/5.03 2.71/3.55/5.03
Reverse Cycle (BTUH)
N/A
COP @ 47°
N/A
SHR
0.82
Indoor CFM (Hi/Med/Low)
0.0" ESP
520/460/360
265 Volt available by special order.
Zoneline
Vertical Unit Nomenclature
®
The Zoneline vertical unit is identified by a model number defining the type of unit, cooling capacity, and electrical information.
When specifying or ordering the Zoneline Vertical unit the use of this nomenclature will assure receiving the correct unit.
EXAMPLE
A
Z
8
Zoneline
Chassis series
®
packaged
85=vertical
terminal unit

Unit type

E= cooling with electric
resistance heat
H= heat pump with electric
resistance heat
W=Cool only
Other components are necessary for a complete
installation - see System Essential Components section.
Listed by
Underwriters'
Laboratories.
2
Electric resistance heat
11,700/11,500 17,900/17,700
10.6/10.6
9.3/9.3
3.2
5.0
N/A
N/A
N/A
N/A
0.79
0.71
590/500/380
600/520/400
Electric resistance heat
11,700
17,900
10.6
9.3
3.2
5.0
N/A
N/A
N/A
N/A
0.80
0.70
590/500/380
600/520/400
5
E

Nominal cooling capacity

09=8,800 BTUH cooling
12=11,700 BTUH cooling
18=17,900 BTUH cooling
Voltage/Phase/Frequency
D= 230/208 Volt, single phase, 60 Hz
E= 265 Volt, single phase, 60 Hz
Heat pumps
8,800/8,600
11,700/11,500 17,800/17,700
10.5/10.5
10.6/10.6
2.5
3.2
8,200/8,000
10,400/10,300 16,400/16,200
3.4
3.4
0.83
0.79
520/460/360
590/500/380
600/520/400
Heat pumps
8,800
11,700
10.5
10.6
2.5
3.2
8,200
10,400
3.4
3.4
0.83
0.79
520/460/360
590/500/380
600/520/400
0
9
D
Heater
configuration
A= Universal heater
See power
connection kits
section
Special Features
C= corrosion protection
Cool only
9,000/8,800
11,700/11,500 17,900/17,700
9.3/9.3
10.5/10.5
10.6/10.6
5.0
2.5
3.2
N/A
N/A
N/A
N/A
3.0
N/A
N/A
0.69
0.81
0.79
520/460/360
590/500/380
17,800
9.3
5.0
16,400
3.0
0.70
A
C
9.3/9.3
5.0
N/A
N/A
N/A
0.71
600/520/400

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents