Mini Specs Power Connection Kits And Nomenclature - GE 6100 Series Data Manual

Packaged terminal air conditioners 2010 contract sales architects and engineers data manual
Table of Contents

Advertisement

Power Connection Kits
230/208-Volt Line Cord Connection Units
Electric
Line Cord
Heat
Kit
BTUH
RAK3153A
8150/7900
RAK3203A
11200/10900
RAK3303A
16000/15450
Electric Heat Amps include electric heater and fan motor current draw.
Each Line Cord Kit has an integral Leakage Current Detection and Interruption (LCDI) or Arc Fault
Current Interrupter (AFCI) device as required by National Electrical Code (NEC) and Underwriters
Laboratories (UL) for units manufactured after August 1, 2004.
265-Volt Sub-Base and Direct Connected Units
Power
Sub-Base
Connection Kit
RAK204E15
RAK5172
RAK204E20
RAK5202
RAK204E30
RAK5302
Electric Heat Amps include electric heater and fan motor current draw.
265-volt units are to be permanently connected in compliance with National Electrical Code and local codes and have a factory-installed junction box on the chassis.
Each 265-volt sub-base kit consists of sub-base with appropriate receptacle for minimum circuit amperage, chaseway to route power connector from sub-base to chassis
and wiring to connect sub-base to building wiring.
265-Volt Power Connection Kit must be ordered separately.
Important
Essential Elements Ordering Overview
230/208-volt line cord connected units — order line cord kit
230/208-volt sub-base connected units — order sub-base
265-volt units — order sub-base and power connection kit
Zoneline
Chassis Nomenclature
®
The Zoneline chassis is identified by a model number defining the type of unit, cooling capacity, electrical information and
optional features included on the unit. When specifying or ordering the Zoneline chassis, the use of this nomenclature will
assure receiving the correct unit.
EXAMPLE
A
Z
6
1
H
Zoneline
Chassis series
packaged
41= deluxe line cool/
terminal
electric heat
61=deluxe line heat pump
chassis
Unit type
E= cooling with electric
resistance heat
H= heat pump with electric
resistance heat
Electric
Electric
Min. Circuit
Protection
Heater
Heat
Watts
Amps
(Amps)
2400/2320
11.0/11.6
3300/3200
15.1/16.0
4700/4530
21.2/22.4
Direct
Connection Kit
RAK5157
RAK5207
RAK5307
1
2
D
A
Nominal cooling capacity
Universal
power connection
07=7,000 BTUH cooling
09=9,000 BTUH cooling
12=12,000 BTUH cooling
15=15,000 BTUH cooling
Special Features
B=base unit
C=corrosion treated
Voltage/Phase/
D= internal
Frequency
condensate
D= 230/208-Volt,
removal (ICR)
single-phase, 60 Hz
system (heat
E= 265-Volt, single-phase,
pump models
60 Hz
only) (not for
coastal areas)
P= Dry Air 25 (4100
Series only)
230/208-Volt Sub-Base and Direct Connected Units
Direct
Sub-Base
Connection
Kit
15
RAK204D15P
RAK4157
20
RAK204D20P
RAK4207
30
RAK204D30P
RAK4307
Electric Heat Amps include electric heater and fan motor current draw.
Units connected through sub-base do not require an LCDI or AFCI device since they are not
considered to be line-cord connected. Each 230/208-volt sub-base kit consists of sub-base with
appropriate receptacle for minimum circuit amperage, chaseway to route power connector from
sub-base to chassis, wiring to connect sub-base to building wiring and a short line cord with 9-pin
connector to connect to chassis and plug into receptacle in sub-base.
Short sub-base line cord may not be used without sub-base.
Junction box for 230/208-volt chassis must be purchased separately.
RAK4002A for 2900, 3900, 4100, and 6100 series units, RAK4002B for 5800 series units.
Electric Heat
Electric Heater
BTUH
Watts
8150
2400
11550
3400
16350
4800
D
geappliances.com
Electric
Electric
Electric
Heat
Heater
Heat
BTUH
Watts
Amps
8150/7900
2400/2320
11.0/11.6
11200/10900
3300/3200 15.1/16.0
16000/15450
4700/4530
21.2/22.4
Electric Heat
Min. Circuit Protection
Amps
9.6
13.3
18.6
Min. Circuit
Protection
(Amps)
15
20
30
(Amps)
15
20
30
3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents