A person desiring access to the program mode will enter the present MASTER CODE. If the master code is valid
the yellow LED will come on and the individual will be prompted with a QUICKBEEP to enter a 3 digit number
corresponding to a SUBMODE. There are 4 groups of SUBMODES. Group 100 is for PROGRAMMING CODES, group 200
is for DELETING CODES, group 300 is MISCELLANEOUS SETTINGS and GROUP 400 is PRINT FUNCTIONS. There are a total
of 26 different submodes to choose from. They are as follows:
SUBMODE
100
101
102
103
104
105
106
108
109
110
SUBMODE
200
299
SUBMODE
300
301
302
SUBMODE
400
401
402
403
404
405
499
Page 9 American Access Systems / Security Brands, Inc.
PROGRAMMING
GROUP 100 SUBMODES (PROGRAMMING CODES)
Program Access Cards (Block Format)
Program Managers Card(s) (Block Format)
Program Sleep Card(s) (Block Format)
Program Relay A Latch Card(s) (Block Format)
Program Relay B Latch Card(s) (Block Format)
Program Relay B Card(s) (Block Format)
Set System Facility Code (3 max.)
Change System Master Code
Change Quick Entry Master Code
Change Quick Delete Master Code
GROUP 200 SUBMODES (DELETING CODES)
Delete Cod Delete Card(s) (Block Format)
Clear APB status
GROUP 300 SUBMODES (MISCELLANEOUS)
Set Relay A Output Time (1/2 to 99 seconds)
Set Relay B Output Time (1/2 to 99 seconds)
Set Clock Time (Military Format)
GROUP 400 SUBMODES (PRINT FUNCTIONS)
Print Audit Trail (Entire Contents of History Buffer)
Print Out All Current Access Cards
Print Audit Trail on Specific Card
Set Printer Baud Rate
Red Printing on Invalid Cards (For AAS idp562 Citizen Printer Only)
Print Out Current Unit Configuration (Prints out Status of Split Relay,
APB, Current Baud Rate, All Manager's and Second Relay Cards)
Clear Entire History Buffer