AAS PROX 2000 II 23-206 User & Installation Manual page 15

Table of Contents

Advertisement

SubMode 309 (QUIET MODE)
NOTE: From the factory, QUIET MODE is enabled.
DESCRIPTION: If you want to hear the good or bad beeps at your desk when an access code is entered at the slave
keypad you can disable the quiet mode. This sub-mode can be toggled on or off by pressing:
(MASTER CODE) + 309(*) + (MASTER CODE)
(*) 1 BEEP AND RED LED ON = FEATURE ENABLED
(*) 2 BEEP AND RED LED OFF = FEATURE DISABLED
SubMode 400 (PRINT AUDIT TRAIL)
NOTE: THE UNIT MUST BE INTERFACED TO A PRINTER TO INVOKE THIS SUBMODE.
DESCRIPTION: The PROX 2000 II is capable of storing up to 1000 transactions in it's history buffer. Once the unit
reaches 1000 transactions the unit will roll over and overwrite the first transaction unless the buffer is cleared (see
submode 499).
To print out the history buffer enter the 4 digit "MASTER CODE" followed by submode "400".
(MASTER CODE) + 400
The unit will continually print out all transactions from first transaction to last. Should you make an entry error, simply
press the * key and reenter the correct data. Once the unit has finished it will respond with a GOODBEEP and exit from
the program mode. To halt printing simply turn the printer off.
SubMode 401 (PRINT OUT ALL CURRENT ACCESS CARDS)
NOTE: THE UNIT MUST BE INTERFACED TO A PRINTER TO USE THIS SUBMODE.
DESCRIPTION: This sub-mode is used to print out all access cards in the system.
To print out all access cards enter the 4 digit "MASTER CODE" followed by submode "401".
(MASTER CODE) + 401
SubMode 402 (PRINT AUDIT TRAIL ON SPECIFIC CARD)
NOTE: THE UNIT MUST BE INTERFACED TO A PRINTER TO INVOKE THIS SUBMODE.
DESCRIPTION: This sub-mode is used to print out the audit trail (history) of a specific card. The unit goes through the
1000 code history buffer and finds when the specific card has been used and prints the times and dates.
To print out the history of a specific card enter the 4 digit "MASTER CODE" followed by submode "402" followed by the
"SPECIFIC CARD".
(MASTER CODE) + 402 + (SPECIFIC CODE)
Example: To print out the history of code 13156 enter:
"MASTER CODE" + 402 + 13156
SubMode 403 (SET PRINTER BAUD RATE)
The default baud rate is 9600. To program in a different baud rate choose from these 4 choices and put in the
number 1 thru 4.
(MASTER CODE) + 403 + (1,2,3 OR 4)
Example: To change to 2400 baud:
Page 15 American Access Systems / Security Brands, Inc.
"309"
"400"
"401"
"402"
"403"
MASTER CODE" + 403 +
1 - 9600 baud
2 - 4800 baud
3 - 2400 baud
4 - 1200 baud

Advertisement

Table of Contents
loading

This manual is also suitable for:

2000 23-206

Table of Contents