AAS PROX 2000 II 23-206 User & Installation Manual page 11

Table of Contents

Advertisement

SUBMODE 103 (PROGRAM LATCH A CARD(S)) (BLOCK FORMAT)
DESCRIPTION: The LATCH A CARD(S) is used to toggle the output state of relay A. In most cases this card will be used
to hold a gate or door open. This card is accepted into the system from either of the slaves. Each time the LATCH A
CARD is entered, the latch A card number, date, and time are logged into the history buffer and the unit toggles the
output state of relay A. This code is not accessible while the unit is in the SLEEP MODE (see submode 102).
NOTE: IN ORDER TO UTILIZE THIS FUNCTION IN A GATE OPERATOR, THE OPERATOR MUST INCORPORATE AN "OPEN
OVERRIDE CIRCUIT".
To program in a new latch A card(s) enter the 4 digit "MASTER CODE" followed by submode "103" then enter the
"STARTING CARD NUMBER" and then the "ENDING CARD NUMBER" you wish to program into the unit.
(MASTER CODE) + 103 + (STARTING CARD NUMBER) + (ENDING CARD NUMBER)
SUBMODE 104 (PROGRAM LATCH B CARD(S)) (BLOCK FORMAT)
DESCRIPTION: The LATCH B CARD is used to toggle the output state of relay B. In most cases this card will be used to
hold a gate or door open. This card is accepted into the system from either of the 2 slaves. Each time the LATCH
B card is entered the latch B card, date, and time are logged into the history buffer and the unit toggles the output
state of relay B. This card is not accessible while the unit is in the SLEEP MODE (see submode 102).
NOTE: IN ORDER TO UTILIZE THIS FUNCTION IN A GATE OPERATOR, THE OPERATOR MUST INCORPORATE AN "OPEN OVER-
RIDE CIRCUIT".
To program in a new latch B card(S) enter the 4 digit "MASTER CODE" followed by submode "104" then enter the
"STARTING CARD NUMBER" and then the "ENDING CARD NUMBER" you wish to program into the unit.
(MASTER CODE) + 104 + (STARTING CARD NUMBER) + (ENDING CARD NUMBER)
EXAMPLE: TO VALIDATE A SINGLE CARD, CARD NUMBER 14.
SUBMODE 105 (PROGRAM RELAY B CARD(S)) (BLOCK FORMAT)
DESCRIPTION: Relay B cards are used to activate relay B. Each time a relay B card is entered into the system, the
relay B card number, date, and time are logged into the history buffer. These cards are not accessible if the unit is in
the SLEEP MODE (see submode 102).
To program in relay B cards enter the 4 digit "MASTER CODE" followed by submode "105" followed by the "STARTING
CARD NUMBER" and then the "ENDING CARD NUMBER" you wish to program into the unit.
(MASTER CODE) + 105 + (STARTING CARD NUMBER) + (ENDING CARD NUMBER)
EXAMPLE: TO VALIDATE CARD NUMBERS 1157 THRU 1170 PRESS:
SUBMODE 106 (SET SYSTEM FACILITY CODE(S))
DESCRIPTION: The facility code must be set, for any of your cards to work with the system. The facility code can
usually be found on the back of your cards. The PROX 2000 can handle a maximum of 3 facility codes.
Note: The facility codes for the unit must reside between 0 and 255.
To program in your facility code(s) simply press in your 4 digit "MASTER CODE" followed by submode "106" followed
by your 3 digit facility code, you can continue to enter facility codes until you have entered the maximum of 3. If you
have less than 3, then when you are done press # to exit.
(MASTER CODE) + 106 + ( 3 DIGIT FACILITY CODE) + ( 3 DIGIT FACILITY CODE)..... # TO EXIT
EXAMPLE: PUT IN FACILITY CODES 115 AND 4.
NOTE: ANOTHER WAY TO PROGRAM IN YOUR FACILITY CODE IS TO PUT IN YOUR MASTER CODE FOLLOWED BY 106 THEN
TOUCH ONE OF YOUR ACCESS CARDS TO THE READER THREE TIMES(BEFORE THE UNIT TIMES OUT, THIS IS PROBOBLY A
TWO PERSON JOB)
Page 11 American Access Systems / Security Brands, Inc.
"103"
1251 + 103 + 0014 + 0014
"104"
1251 + 104 + 0014 + 0014
"105"
1251 + 105 + 1157 + 1170
"106"
1251 + 106 + 115 + 004 + # TO EXIT

Advertisement

Table of Contents
loading

This manual is also suitable for:

2000 23-206

Table of Contents