AAS PROX 2000 II 23-206 User & Installation Manual page 13

Table of Contents

Advertisement

DESCRIPTION: Quick delete mode is another way to delete individual access cards from the system. The factory
default QUICK DELETE MASTER CODE is 1 2 5 3. (To change the quick delete master code see sub-mode 110.
To delete access cards enter the 4 digit " QUICK DELETE MASTER CODE" followed by the "CARD NUMBER" you wish to
delete followed by the next "CARD NUMBER" and so on until you are finished and then press the # key to exit.
(QUICK DELETE MASTER CODE) + (CARD NUMBER) + (CARD NUMBER)... # TO EXIT
EXAMPLE: DELETE ACCESS CARD NUMBER 95
SubMode 299 (CLEAR APB STATUS)
DESCRIPTION: This sub-mode is useful if a mistake is made and the Anti-PassBack status of all cards needs to be reset.
To erase the APB status of all cards in memory, enter the 4 digit "MASTER CODE" followed by submode "299" and then
reenter the 4 digit "MASTER CODE".
(MASTER CODE) + 299 + (MASTER CODE)
The LED's will flash on and off while the memory is being cleared and the unit will respond with a GOODBEEP when
finished. An ERROR will occur and the unit will exit the program mode if the second master code is incorrect.
SubMode 300 (SET RELAY A OUTPUT TIME)
DESCRIPTION: The output time of relay A can be set anywhere from 1/2 to 99 seconds. The factory default is 1/2
second. In most cases this is adequate for gate operators. However, with door strikes and maglocks a longer output
time may be desired.
To set the output time of relay A in seconds enter the 4 digit "MASTER CODE" followed by submode "300" and then a 2
digit number corresponding to the number of seconds.
(MASTER CODE) + 300 + (SECONDS)
The unit will respond with a GOODBEEP and exit from the program mode once the seconds for relay B has been
accepted. If you enter 00 for seconds the output time is set to 1/2 second. Should you make an entry error, simply
press the * key and reenter the correct data.
SubMode 301 (SET RELAY B OUTPUT TIME)
DESCRIPTION: The output time of relay B can be set anywhere from 1/2 to 99 seconds. The factory default is 1/2
second. In most cases this is adequate for gate operators. However, with door strikes and maglocks a longer output
time may be desired.
To set the output time of relay B in seconds enter the 4 digit "MASTER CODE" followed by submode "301" and then a 2
digit number corresponding to the number of seconds.
(MASTER CODE) + 301 + (SECONDS)
The unit will respond with a GOODBEEP and exit from the program mode once the seconds for relay B has been
accepted. If you enter 00 for seconds the output time is set 1/2 second. Should you make an entry error, simply press
the * key and reenter the correct data.
SubMode 302 (SET CLOCK TIME)
To set the clock time enter the 4 digit "MASTER CODE" followed by submode "302" then the "HOURS" and "MINUTES" of
the day in military format.
(MASTER CODE) + 302 + (HOURS) + (MINUTES)
The unit will respond with a GOODBEEP and exit from the program mode after the TIME has been accepted into the
unit. Should you make an entry error, simply press the * key and reenter the correct data.
Page 13 American Access Systems / Security Brands, Inc.
"QUICK DELETE MODE"
1253 + 0095 + #
GROUP 300 (MISCELLANEOUS)
Example.
8:23 a.m. = "08" + "23"
5:00 p.m. = "17" + "00"
"299"
"300"
"301"
"302"

Advertisement

Table of Contents
loading

This manual is also suitable for:

2000 23-206

Table of Contents