DRAIN CONNECTION

Standpipe
Make sure that the drain hose is not inserted too far inside the standpipe. If the end of the drain hose is
provided with "support fins", make sure these are fully inserted in the standpipe.
Recommended height for
standpipe 500 mm (20")
FIGURE:
Recommended height for standpipe: 500mm (20'')
This prevents the hose from jolting during installation and use.
Do not position the standpipe near electrical sockets. MAKE SURE that the drain hose is not kinked and
that it is positioned as shown in the figure.
The standpipe must have a diameter of at least 38 mm (1½''). It must be installed as shown in the figure,
be provided with a trap and drain into the same drain system as the sink. IT MUST NOT be connected to
the sink drain.
Sink drain system
For draining below the sink:
Before connecting the drain hose, eliminate any internal restrictions in order to prevent the build-up of any
foreign material which could lead to blockages.
800 mm
Spigot height
(31 ½ In.)
600 mm min.
min.
FIGURE:
Tap height 600 mm min.
Fix the drain hose securely using a hose clamp with screws.
Service Manual
Manual LFF 825 IT/HA
65 mm (2 ½") max.
40 mm (1 ½") min.
Fit hose to waste
securely using a
'Jubliee type clip