Cleanburn Norreskoven Installation And Operating Instructions Manual

Cleanburn Norreskoven Installation And Operating Instructions Manual

Multifuel stove

Advertisement

N Ø R R E S K O V E N
N Ø R R E S K O V E N
N Ø R R E S K O V E N
N Ø R R E S K O V E N
M U L T I F U E L
M U L T I F U E L
M U L T I F U E L
M U L T I F U E L
Installation and Operating Instructions
An accredited competent person must carry out the installation of this appliance;
alternatively, your local Building Control Officer can approve the completed
installation, should a non-accredited engineer undertake the installation. It is an
offence, under UK law, not to comply with this advice. Please hand these
instructions to the stove user when the installation is complete. Leave the system
ready for operation and instruct the user in the correct use of the appliance and
operation of controls.
S T O V E
S T O V E
S T O V E
S T O V E
v03.10

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Norreskoven and is the answer not in the manual?

Questions and answers

Alan Wesley Hampshire
January 30, 2025

If the riddling is buckled will that effect the stoves efficiency . Do I need a new plate even though the back bricks remain intact ?

1 comments:
Mr. Anderson
February 10, 2025

The information provided does not explicitly mention the effect of a buckled riddling plate on the efficiency of a Cleanburn stove. However, for optimal performance, the riddling mechanism must function correctly to ensure proper airflow through the firebed. If the riddling plate is buckled, it may impede ash removal and airflow, potentially reducing efficiency. Regarding the back bricks, if they remain intact, replacing them may not be necessary, but a new riddling plate may be required to maintain proper stove operation.

This answer is automatically generated

Summary of Contents for Cleanburn Norreskoven

  • Page 1 N Ø R R E S K O V E N N Ø R R E S K O V E N N Ø R R E S K O V E N N Ø R R E S K O V E N M U L T I F U E L M U L T I F U E L M U L T I F U E L...
  • Page 2: Technical Specification

    Nørreskoven Technical Specification Stove Mass 100 kg DS/EN 13240 Total Efficiency 82.0 % Nominal Heat Output 4.9 kW Mean CO Emission (at 13% O 0.10 % Mean OGC Emission (at 13% O 96 mg/nm Mean Flue Gas Temperature 220 °C Flue Gas Mass Flow 4.7 g/s (Figures based on a fuel load of 1.4 kg wood logs with primary air closed and secondary air 50% open)
  • Page 3: Flue Collar

    Assembly Instructions PLEASE READ THESE INSTRUCTIONS CAREFULLY It is important that your stove is correctly installed, as Cleanburn Stoves cannot accept responsibility for any fault arising through incorrect use or installation. Flue Collar Wind the eight M6 studs supplied into the fixing holes in the flue collar and blanking plate until finger tight.
  • Page 4 Removing Internal Parts This set of instructions explains the removal sequence that you will need to employ when servicing your Cleanburn stove. 1. Open the stove door(s) and remove the ash pan. 2. Remove the baffle by pulling it forwards and sliding it to the left until the right side of it clears the baffle support and then lowering it into the firebox and removing it (a).
  • Page 5 Cam hole plate 2. Remove the side castings by lifting them upwards and out (g). 3. Remove the front plate by lifting it out. On double-door stoves it will be necessary to push the front plate towards the back of the stove to free it from the location pins (h) before lifting it out (k).
  • Page 6: Installation Instructions

    Installation Instructions These instructions cover the basic principles to ensure satisfactory installation of the stove, although detail may need slight modification to suit particular local site conditions. In all cases the installation must comply with current Building Regulations, Local Authority Byelaws and other specifications or regulations as they affect the installation of the stove.
  • Page 7: Installation

    Installation Chimney The chimney height and the position of the chimney terminal should conform to Building Regulations. Check that the chimney is in good condition, dry, free from cracks and obstructions. The diameter of the flue should not be less than 150mm and not more than 230mm. If any of these requirements are not met, the chimney should be lined by a suitable method.
  • Page 8: Material Clearances

    Material Clearances Your stove must be installed on a floor with adequate load-bearing capacity. If the existing construction does not meet this pre-requisite, suitable measures (e.g. load distributing plate) should be taken to achieve it. Care should be taken to level the stove using the adjusting screws in the feet. FREE-STANDING FIREPLACE RECESS Plan view:...
  • Page 9: Fuel Storage

    Fuel Storage log storage recess Fuel may be placed in the log storage recess underneath the European variant. The logs should be stacked in such a way that they do not touch the heat shield at the top of the recess. Important! - Fuel must not be stored underneath the Traditional or Pedestal variants.
  • Page 10: Aerosol Sprays

    Operating Instructions This appliance is not suitable for use in a shared flue This appliance should not be operated with the doors open Aerosol Sprays Do not use an aerosol spray on or near the stove when it is alight. Air Controls This stove has been designed to burn cleaner and more efficiently than a conventional wood burning stove.
  • Page 11: Multifuel Grate

    Multifuel Grate Your Cleanburn Stove is fitted with a locomotive type grate. So that de-ashing can be carried out cleanly and easily, it is riddled from the outside of the stove with the doors closed. The grate is designed to burn both wood and solid fuels.
  • Page 12: Wood Burning

    Loading the Stove (Solid Mineral Fuel) Solid mineral fuel should be placed in the stove so that there is no more than a 30° incline of the fuel bed from front to back. It should not be stacked above the level of the rear firebrick as this may result in damage to the stove.
  • Page 13: Extinguishing The Fire

    Air Controls (Wood) Wood burns most efficiently with the primary control in the closed position and the secondary control approximately 60% open. Moving the secondary control will control the burn rate of the stove. The secondary air lever should not be completely closed unless the primary air lever is also in the closed position.
  • Page 14: In The Event Of A Chimney Fire

    Important! – Do not fit an extractor fan in the same room as this appliance. IN THE EVENT OF A CHIMNEY FIRE Raise the alarm to let others in the house know. • Call the Fire Brigade. • Reduce the appliance-burning rate by closing all air controls. •...
  • Page 15: General Maintenance

    Check the rope around the door and glass. If rope is becoming detached, use proprietary rope glue to re-attach it. If the rope is in a poor condition, a replacement rope kit may be ordered from the Cleanburn Stoves spares range. Annually...
  • Page 16: Troubleshooting

    If the stove is fitted in place of an open fire, then the chimney should be swept one month after installation to clear any soot falls which may have occurred due to the difference in combustion between the stove and the open fire. Periods of Prolonged Non-Use - If the stove is to be left unused for a prolonged period of time then it should be given a thorough clean to remove ash and unburned fuel residues.
  • Page 17: Stove Spares

    STOVE SPARES SINGLE DOOR Door Handle Assembly Single Door HMS04/002 Door Handle HCE05/035 Handle Spacer HCE05/036 Handle Nut HCE05/037 Door Glass Shaft, Door Handle HMS04/053 HCE05/038 Circlip Glass Gasket FLRX07 HMS04/055 M8 Full Nut FSHM08 Door Catch HMS04/037 Glass Clip & Screw HHR08/046 FSJM05008SS DOUBLE DOORS...
  • Page 18 PRIMARY AIR VALVE Slider Knob Front Shaft HCE05/040 HCE05/033 Gasket Control Boss HMS04/046 HCE05/034 Cast Iron Valve HMS04/044 Support HCE05/031 Rear Shaft HCE05/032 BODY ASSEMBLY - PART SECTION - MULTIFUEL Flue Gaskets Top Air Parts Flue Collar CH05/042 Slider CH05/010 HCR06/072 Flue Cover Slider Shaft...
  • Page 19 QUARTER TURN DOOR HANDLE - DOUBLE DOOR - MULTIFUEL - PARTS Catch End HCE09/089 Catch Shaft HCE05/082 M12 Half Nut FNLM12Z Catch Collar Catch Boss HCE09/092S HCE09/090S Snap Ring FLRWM0160 3mm x 10mm Roll Pins 4mm x 14mm Roll Pin FPGM03010 FPGM04014 Catch Spacer...

Table of Contents