PSU-PC19 V2.0 Features
•
140 Watt Dual Output Regulator
•
Jumper selectable main output of +18/+19/+20V
•
Jumper selectable secondary output of +12V/+13.5V or +5V
•
A THIRD output of +5V/15W can be added by installing the optional P5V regulator.
•
Survives Engine Cranking under full load over entire temperature range
•
Includes sophisticated Startup/Shutdown Controller
•
Includes sturdy aluminum chassis with variable speed fan suitable for car environment
•
Field upgradeable flash microprocessor
•
Low battery monitor prevents drained battery, even during Standby
•
"Deadman Timer" automatically exits Standby and turns the unit off after 3 days if jumper is set.
•
"Anti Thump" delayed remote control for audio amplifiers
•
Remote "Pulse Start" from wireless device or car alarm/remote start system
•
Over current protection on both outputs with graceful forced shutdown of main output
•
Powers both your Xenarc SC8 AND your Xenarc LCD screen or USB devices
•
Full, safe support for Windows Standby mode including auto shutdown if PC fails to shutdown
•
Over voltage surge suppression on battery input for protection of harsh automotive environment
•
User replaceable fuse on battery input to protect your car from internal short circuits
•
Now includes an internal ACPI isolation relay to provide full compatibility with the ACPI/power switch interfaces with
Xenarc PCs. No need for an external relay!
•
Now includes "plug and play" cable (CNX-CA-XSC8) for connecting power and ACPI (power button) to Xenarc SC8.
(Red)
+12V Battery
(Red)
(Blk)
GND
(Blk)
(Yel)
Ignition
(Blue)
Pulse Start
CarNetix PSU-PC19 V2.0 Installation Manual
PSU-PC19
Figure 3 PSU-PC19 Block Diagram
- 6 -
(Red)
Primary Output
(Red)
+18V/+19V/+20V
(Blk)
(Blk)
GND
(Brn)
Secondary Output
+5V/+12V/+13V
(Wht)
Not used
(Grn)
ACPI (non-isolated)
(Blu)
DLYON
(Grn)
ACPI (isolated)
(Blk)