SCHOLTES MGN 31 HK Installation & User Manual

SCHOLTES MGN 31 HK Installation & User Manual

Gas domino built-in hob

Advertisement

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MGN 31 HK and is the answer not in the manual?

Questions and answers

Summary of Contents for SCHOLTES MGN 31 HK

  • Page 3 Maintenance Instructions for Installer, 4-5 Installation Positioning Gas connection Electrical connection MGN 31 HK Specification, 6 MGN 321 HK Trouble Shooting, 7 THIS APPLIANCE IS CONCEIVED FOR DO- MESTIC USE ONLY. THE MANUFACTURER SHALL NOT IN ANY WAY BE HELD RE-...
  • Page 4: Important Safety Instruction

    Important Safety Instruction following instructions very 8. If another built-in appliance (e.g. dishwasher, washer, etc) is to be installed under the gas important to safety operation of gas hob. hob, keep a clearance of at least 15mm from Please read through them carefully. For the bottom of the gas hob.
  • Page 5 13. We recommend the use of pots and pans with iv. Dry burner heads completely with dry a diameter matching that of the burner, thus cloth after washing. Burner flame holes preventing the flame from escaping from the must be free from water lest combustion bottom part and surrounding the pot.
  • Page 6: Instructions For Use

    Instructions For Use Usage – Gas burners Maintenance MGN 31 HK : This model allows synchronized Allow the appliance to cool down before performing control of double ring and independent control of any maintenance and cleaning. inner ring. Prior to any cleaning and maintenance operation, disconnect the appliance from the power supply.
  • Page 8: Instructions For Installer

    Instructions For Installer Installation Electrical connection (Fig. 3) This appliance is not provided with flue gas Prior to carrying out the electrical connection, please discharge. It is recommended that it is installed in ensure that: sufficiently aerated places. The quantity of air ...
  • Page 9: Specification

    Specification Model MGN 31 HK MGN 321 HK Gas Type TOWN GAS (G110) 3.0 kW (upper burner) Heat Input 4.0 kW 2.0 kW (lower burner) Gas Supply Pressure 1.5 kPa Governor Outlet Pressure 1.0 kPa Gas Inlet Connection 1/2” B.S.P (Male)
  • Page 10: Troubleshooting

    Trouble Shooting Fault Cause Remedy 1. Spark electrode is wet especially 1. Dry the electrode with tissue or dry cloth. in seasons of high humidity. No ignition 2. Turn on power. 2. Power is off. Fully press and turn the gas control knob to Flame cannot Control knob is not fully pressed.

Table of Contents