Mechanical Disassembly
b Power, Ballast, Lamp Cover Sw Board, Thermal Sw(SW902) removal
1. Remove the  screws A( Tx8) (top side), remove the  screws B (Tx8)
(bottom side) and remove screw G(Tx6) to remove the Power board assy.
. Remove the Isolation sheet.
. Remove  screws C(Tx6) to remove the Ballast board.
4. Remove the screw E (Tx6) and remove the Lamp cover switch board.
remove the screw F (Tx6) and remove the thermal switch (SW90).
A
C
Power board
Ballast board
B
-15-
Isolation sheet ( sheets)
G(Tx6)
C(Tx6)x
A(Tx8)x
Lamp cover
switch board
F (Tx6)
E (Tx6)
B (Tx8)x
Themal switch
(SW90)
Fig.5