Mechanical Disassembly
v Optical unit, NETWORK board, Temp., Line Filter board,Fans removal
1. Remove 5 scrws A(T3x8) to remove the Optical unit.
2. Remove 2 screws B(T3x8) to remove the NETWORK board.
3. Remove 2 screws C (T3x8) and 4 hooks on the duct and then remove the Duct top.
Remove the Line filter board.
4. Remove 2 screws D(T3x6) to remove the Noise filter and remove screw E (T3x6)
to Temp. board.
5. Remove fans (FN903, FN904, FN905) and SP901.
Projection lens
(M2.5x8)x4
B
B (T3x8)x2
NETWORK board
A
A
C
C (T3x8)x2
Duct top
FN905
FN904
-14-
A(T3x8)x5
Optical unit
A
A
D (T3x6)x2
D
Temp. board
FN903
E (T3x6)
Duct bottom
Line filter board
Noise filter
SP901
Fig.4