When removing the outdoor unit, two ropes are needed to hang the unit along the four ways. In order to
avoid the excursion, the angle between the ropes should be less than 40 degree.
Please use M12 to tight the support fundus.
3). Refrigerant pipe connection
Note:Do not loosen the cap of the pipes when connecting the pipes between
the indoor unit and the outdoor unit. Connecting the pipes as soon as
possible after loosening the cap of the pipes to avoid the entering of water
and dusk. A metal pipe should be utilized if a pipe should be installed
through a wall.
The connection of the pipes should confirm to the following principles:
Make sure to lessen the length of connecting pipe, the height difference between the indoor and outdoor unit,
Fig 29 Schematic for the installation of the outdoor unit
>300
Fig 30 Schematic for the installation of the outdoor unit
Fig 31 Crane way schematic
>300
>300
37