  • Page 2 Introduction Thank you for purchasing the 2K thermocouple alarm thermometer. Please take a few minutes to browse through this user manual before you begin to operate the meter to ensure that you are familiar with how best to operate the meter as accurately and safely as possible.
  • Page 3 and the battery will need to be replaced. 3. To keep the instrument clean, wipe the case with a dry cloth and detergent, do not use abrasives or solvents. 1.1.2 Maintaining the product  When not using the instrument for a long time, please remove the battery and avoid storing in high temperature and high humidity environments.
  • Page 4 5. Sample rate: 1 second 6. Auto power off: about 20 minutes. (Default set to auto-off disabled. Settable by user.) 7. Low battery indicator 8. Operating environment: 0°C ~ 50 °C (32°F~122°F), 0 ~ 80%RH 9. Storage environment: -20°C ~ 60°C (-4°F~140°F), 0 ~ 80%RH 10.
  • Page 5: Names Of Parts

    Names of parts  Instrument Familiarization 1. Sensor cover 2. Temperature input connectors 3. LCD display 4. Function keys...
  • Page 6  LCD Display The meaning of the symbols represented by the following: 1. Indication to the high or low temperature alarm setting 2. Type of thermocouple 3. Display zone (T1) 4. Display zone (T2) 5. Maximum / Minimum 6. Back light indication 7.
  • Page 7: Operation Instruction

    Operation Instruction NOTE: After abrupt ambient temperature changes, allow meter at least 20 minutes to equilibrate to the new ambient condition before taking measurements. This allows ample time for the internal CJC to equilibrate to the new ambient temperature. Turning the Unit On and Off Press the ON/OFF button momentarily to power the unit on.
  • Page 8 Light button while powering the unit on. A single beep sound will confirm that the Auto-Off is now disabled. Max/Min Function The TW8060 includes a Max/Min function. While the unit is powered on, it will continuously record the maximum and minimum recorded temperature. The Max/Min temperatures will be stored until they are cleared by the user, even if the power is shut off.
  • Page 9 clear/reset the Max/Min function after replacing probes. Alarm On/Off After the alarm high and low values are set the user can turn the alarm function on or off. To turn the alarm monitoring on press the ALARM ON/OFF button and the word LIMIT will be displayed directly above the T1 temperature display.
  • Page 10 NOTE: To reset the alarms to factory default settings, press and hold the ALARM HI/LO button for 3 seconds. CLER will be displayed momentarily. Setting the Display Units The TW8060 will display temperature in two scales, Fahrenheit and Celsius. To switch from one scale to the...
  • Page 11: Maintenance

    MIN and alarm settings will convert to the new scale. Turning on the Backlight The TW8060 is enabled with a backlight for ease in viewing the display in dark environments. The backlight will shut off after 30 seconds to preserve battery life. To turn on the backlight, press the LIGHT button momentarily.
  • Page 12: Battery Replacement

    NOTE: This unit is not designed for complete submersion or washing in water. 2. BATTERY REPLACEMENT Use the following procedure: When the battery voltage drops below proper operating range the symbol will appear on the LCD display and the battery should be replaced. •...
  • Page 13 1762 W. 20 S. #100 Lindon, UT 84042 Ph: 801-756-7705 Fx: 801-756-8948 www.thermoworks.com...