ThermoWorks IP-PRO-100 Operating Instructions

Industrial hi-temp infrared thermometer

Advertisement

Quick Links

IR-PRO-100 Industrial Hi-Temp Infrared Thermometer - Operating Instructions
For Model with thermocouple socket
The non-contact infrared thermometer is the ultimate tool for temperature measurements. It can measure from 100 to 1800
o
(212 ~3272
F) in the distance of 100:1 DS (Distance to Spot) ratio. Furthermore, the memory mode can record and display the
specific measurement with emissivity. There are many mathematical modes for the Infrared function.
* Please remember to keep away from children and don't use it for safety related applications.
(Default Screen)
Simply aim the thermometer at the
measure target with Lens (11) and press
Meas. key (8) to display the surface
temperature. The Distance:Spot is 100:1.
The two laser points are the reference for
the target spot size. Please make sure
the target area is within the field of view.
FUNCTION
Press Emissivity key (
) for setting the emissivity
3
Press Emissivity key (
), then press Up key (
3
(
) to confirm it. The emissivity can be changed from 0.10 (10E) to 1 (100E).
5
Press Mode key (
) for scrolling more display function as follows.
5
Here will show the emissivity data. (The default emissivity is 0.95.)
Press Mode key (
) for the Maximum (MAX), Minimum (MIN), Different between MAX and MIN (DIF) and
5
Average (AVG) modes. During the measurement, the special modes reading will be displayed beside the
mode icon.
Press Up key (
) or Down key (
) key to change the High Alarm (HAL) or Lo Alarm (LAL), then press Meas.
4
2
key (
) to confirm it. When the reading is outside the High Alarm (HAL) or Lo Alarm (LAL) limit. The High or
8
Low icon will flash and you will hear a beep sound.
Connect the thermocouple with Thermocouple socket (
display the temperature automatically without pressing any button. To see the minimum or maximum data during
the probe measurement, please hold down the Up key (
After measure high temp, the probe may remain HOT for a while.
Press measurement trigger and release to store the reading that you want to save. (Note – while in Memory (M00)
function readings are not taken). Once the reading is shown on the display, press the MODE button until the M00
(Memory) is displayed. To store the reading press the measurement trigger and the current reading along with the
emissivity setting will be saved to the M01 location and all other readings will be bumped up one memory location
to allow the current reading to be saved. (Note – the current reading can only be stored to one location).
To view stored readings press the MODE button until M00 (Memory) is displayed. Press the Up and Down button
to view readings. To clear all memory data, press and hold the UP and Down arrows simultaneously for 2
seconds while in the Memory function.
** The thermometer will automatically shut off if left idle for more than 60sec.ADD VALUE
Press Up key (
) for LOCK mode ON/OFF. The lock mode is particularly useful for continuous
4
In MAX, MIN, DIF,
monitoring of temperatures for up to 60 minutes.
AVG mode:
o
Press Down key (
) for
C or
2
) for backlight function ON/OFF
In all modes: First
and press Up key (
4
hold on the Meas.
and press Down key (
) for laser function ON/OFF.
2
key (
)
8
(With flash light be turned on in the same time as laser )
) or Down key (
) to set the emissivity, then press Mode key
4
2
) and put the probe in/on the target, the thermometer will
7
) or Down key (
).
4
2
o
F transferred.
CAUTION
1. WHEN DEVICE IS IN USE, DO NOT LOOK DIRECTLY INTO THE TWO LASER BEAMS–PERMANENT EYE DAMAGE MAY RESULT.
o
C
2. USE EXTREME CAUTION WHEN OPERATING THE LASER.
3. NEVER POINT THE DEVICE TOWARDS ANYONE'S EYES.
4. KEEP OUT OF REACH OF ALL CHILDREN.
STORAGE & CLEANING
It should be stored at room temperature. The sensor lens is the most delicate part of the thermometer. The lens should be kept clean at all times,
care should be taken when cleaning the lens using only a soft cloth or cotton swab with water or medical alcohol. Allowing the lens to fully dry
before using the thermometer. Do not submerge any part of the thermometer.
LCD ERROR MESSAGES
The thermometer incorporates visual diagnostic messages as follows:
'Hi' or 'Lo' is displayed when the temperature being measured is outside of the settings of HAL and LAL.
'Er2' is displayed when the thermometer is exposed to rapid changes in the ambient temperature. 'Er3'
is displayed when the ambient temperature exceeds 0
」 「
should be allowed plenty of time (minimum 30 minutes) to stabilize to the working/room temperature.
Error 5~9, for all other error messages it is necessary to reset the thermometer. To reset it, wait for auto power
off, remove the battery and wait for a minimum of one minute, reinsert the battery and turn on. If the error
message remains please contact the Service Department for further assistance.
'Hi' or 'Lo' is displayed when the temperature being measured is outside of the measurement range.
」 「
BATTERIES
The thermometer incorporates visual low battery indication as follows:
'Battery OK': measurements
are possible
When the 'Low Battery' icon indicates the battery is low, the battery should be replaced immediately with AA, 1.5V batteries. Please note: It is
important to turn the instrument off before replacing the battery otherwise the thermometer may malfunction.
Dispose of used battery promptly and keep away from children.
SPECIFICATION
e t I
m
Measurement Range
Operating Range
Accuracy (Tamb=23±3°C)
Emissivity Range
Resolution
Response Time (90%)
Distance:Spot
Memory
a B
e t t
y r
L
e f i
Dimensions
Weight
Note:
Under an electromagnetic field of 3V/m from 700 to 1,000 MHz the maximum error is +/-30°C (54
EMC/RFI: Readings may be affected if the unit is operated within radio frequency electromagnetic field strength of approximately 3 volts per
meter, but the performance of the instrument will not be permanently affected.
www.thermoworks.com
1762 W. 20 S. #100 | Lindon, UT 84042
801-756-7705
o
C (32°F) or +50
'Battery Low': battery needs to be
'Battery Exhausted': measurements are not
replaced, measurements are still possible
Thermocouple Probe Scan function
N
n o
c -
n o
a t
t c
f n I
r a r
d e
S
a c
f n
n u
i t c
n o
(K type; a bead wire included.)
K Type: -64 to +1400°C (-83.2 to +2552°F)
o
o
100 to +1800
C (212 to +3272
F)
Bead : -50 to +250°C(-58 to +482°F)
0 to +50°C (32 to +122°F)
+/-1% of reading or 1°C (1.8°F) whichever is
±2% of reading
greater (Test under Tamb=23±6°C)
0.95 default – adjustable 0.1 to 1 step .01
0.1°C/0.1°F at -83.2 to 999.9(°C/°F), otherwise 1°C/1°F
1 sec.
100:1
Detailed 24 Memories with Temperature & Emissivity
y T
. p
8 1
, 0
m
n i
1
0 4
o h
r u
c s
n o
n i t
o u
s u
u
e s
l A (
a k
n i l
, e
t i w
o h
t u
a L
233.8*207.5*60.6mm(9.20×8.17×2.38 inch)
550 grams(19.40 oz) including batteries (AA*2pcs)
o
F), from 1.4∼1.5 GHz the maximum error is +/- 6
o
C (122°F). The thermometer
possible
e s
a r
d n
a B
k c
i L
h g
) . t
o
o
C (10.8
F ).
Ref.No.:032011

Advertisement

loading

Summary of Contents for ThermoWorks IP-PRO-100

  • Page 1 AVG mode: Press Down key ( ) for C or F transferred. www.thermoworks.com ) for backlight function ON/OFF In all modes: First and press Up key ( 1762 W. 20 S. #100 | Lindon, UT 84042 hold on the Meas.
  • Page 2 CERTIFICATE OF CONFORMANCE ThermoWorks conducts quality assurance system under ISO 9001:2000 certified quality system and fully follow ISO GUM (Guide to the Expression of Uncertainty in Measurement) to evaluate the uncertainty of temperature and resistance standards, guarantee performance as below;...