Cybernet iOne-MP171 User Manual

Ione-medical panel pc

Advertisement

Quick Links

iOne-Medical Panel PC
iOne-MP171
USER'S MANUAL
Copyright©,2008. All rights reserved
All other brand names are registered trademarks of their respective owners.

Advertisement

Table of Contents
loading

Summary of Contents for Cybernet iOne-MP171

  • Page 1 Panel PC iOne-MP171 USER’S MANUAL Copyright©,2008. All rights reserved All other brand names are registered trademarks of their respective owners.
  • Page 2 Acknowledgments Intel® and Core 2 Duo and Core Solo are registered trademarks of Intel® Corporation. IBM, PC/AT, PS/2 are trademarks of International Business Machines Corporation. Microsoft® Windows is a registered trademark of Microsoft® Corporation. RTL is a trademark of Realtek Semi-Conductor Co., Ltd. C&T is a trademark of Chips and Technologies, Inc.
  • Page 3: Fcc Classb

    FCC Class B This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 18 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a residential environment. This equipment generates, uses and can radiate radio frequency energy.
  • Page 4: Safety Instructions

    Safety Instructions Greeting & Setup Thank you for purchasing the iOne-MP171 unit. We wish that this unit will be durable and reliable in providing your medical application needs. Please follow the instructions below to ensure the unit continues to have high performance.
  • Page 5 3. Before suspending the unit, make sure the material used for suspension is sturdy and stable. If not properly suspended, the display unit may fall and cause serious injury to people standing nearby as well as to the unit itself. 4.
  • Page 6 Please use only the power cord provided by the dealer to ensure safety and EMC compliance. Various Factors of Environment 1. Do not insert objects into the openings. 2. Do not have liquids seep into the internal areas of the Monitor display unit.
  • Page 7 Cleaning the unit (1) Remember to turn off the power source and to unplug the cord from the outlet before cleaning the unit. (2) Carefully dismount the unit or bring the unit down from suspension to clean. (3) Please use a dry soft cloth to clean the unit. (4) Take a dry cloth and wipe the unit dry.
  • Page 9 Caution: DO NOT LEAVE THIS EQUIPMENT IN AN UNCONTROLLED ENVIRONMENT WHERE THE STORAGE TEMPERATURE IS BELOW -20° C (-4° F) OR ABOVE 60° C (140° F). THIS MAY DAMAGE THE EQUIPMENT. This equipment shall not be used in life support systems. The user is not to touch SIP/SOPs and the patient at the same time.
  • Page 10: Table Of Contents

    Table of Contents ..................CKNOWLEDGMENTS FCC C B ....................LASS ................AFETY NSTRUCTIONS INTRODUCTION ..................1 ................. 1 RODUCT ESCRIPTION ....................2 ACKAGE LIST ......................3 EATURES ..................... 4 PECIFICATIONS ................7 LEANING ISINFECTING ...................... 8 IMENSION ....................9 YSTEM ...................
  • Page 11: Introduction

    Introduction Product Description The iOne-MP171 Medical Panel PC are based on Intel Core 2 Duo processor which deliver a performance improvement of more than 100 percent compared to systems running traditional single-core processors. With two cores, or computing engines, iOne-MP171 can simultaneously execute two computing tasks.
  • Page 12: Package List

    Package List Before you begin installing your Medical Station, please make sure that the following items have been shipped: • The iOne-MP171 Medical Panel PC • One CD containing user manual, QIG, chipset drivers • Power Adapter x 1 (Mf:Sinpro, type/model: MPU100-105) •...
  • Page 13: Features

    100 Series Double Pivot Wall-Mount (optional) 100 Series Single Pivot Wall-Mount (optional) LX Wall Mounting Arm (optional) LX Desk Mounting Arm (optional) DS 100 Dual-Monitor Desk Stand (optional) Resistive touch screen (optional) Plastic construction with medical outlook color _____________________________________________________________________ Cybernet iOne-Medical PC Features Page 3...
  • Page 14: Specifications

    Specifications Hardware Specifications Display 17” 400 nits SXGA color TFT LCD ® iOne-MP171: Intel Core 2 Duo T7500 2.2GHz CPU Support ® Intel Celeron M550 2.0GHz 2.5” Hard Disk Drive (SATA-150) Disk Drive Space Compact Flash Card reader One Mini PCI slot; One PCI expansion,...
  • Page 15: Mechanical Specifications

    Non-operating: 50g/1.76 oz, 11 ms, half sine wave 3 feet (1 Corner, 3 Edge, 6 Surface) Drop EMI / Safety CE / FCC Class B/UL 60601-1/EN 60601-1 iOne-MP171: Under 35 db (full operation) Noise Operational: 6,000 feet Altitudes Shipping: 40,000 feet For Adaptor: AC100~240 V, 47 ~ 63 Hz, 1.25A max.
  • Page 16 Touch Screen (Optional) Type 8-wire, Analog Resistive Interface USB interface Resolution 2048 x 2048 Light Transmission > 75% Life Time 1 million activations _____________________________________________________________________ Specification Cybernet iOne-Medical PC Page 6...
  • Page 17: Cleaning/Disinfecting

    2. Prepare agent per manufacturer’s instructions or hospital protocol. Cautions: Do not immerse or rinse the iOne-MP171 and its peripherals. If you accidentally spill liquid on the device, disconnect the unit from the power source. Contact your Biomed regarding the continued safety of the unit before placing it back in operation.
  • Page 18: Dimension

    Dimension _____________________________________________________________________ Dimension Cybernet iOne-Medical PC Page 8...
  • Page 19: System View

    System View Front View Webcam Control button at front panel From left to right 1. Brightness down 2. Brightness up 3. Power 4. Volume down 5. Volume up _____________________________________________________________________ Cybernet iOne-Medical PC System View Page 9...
  • Page 20: Rear View

    Rear View VESA 75/100 I/O parts _____________________________________________________________________ System View Cybernet iOne-Medical PC Page 10...
  • Page 21: Side View

    Side view _____________________________________________________________________ Cybernet iOne-Medical PC System View Page 11...
  • Page 22: Disconnect Device

    Disconnect Device Unplug the power cord from the power adapter jack to disconnect the device. _____________________________________________________________________ Disconnect Device Cybernet iOne-Medical PC Page 12...
  • Page 23: Bios Setup

    BIOS Set up The Award BIOS provides a Setup utility program for specifying the system configurations and settings. The BIOS ROM of the system stores the Setup utility.
  • Page 24 These defaults have been carefully chosen by both Award and your system manufacturer to provide the absolute maximum performance and reliability. Changing the defaults could cause the system to become unstable and crash in some cases. _____________________________________________________________________ BIOS Setup Cybernet iOne-Medical PC Page 14...
  • Page 25: Standard Cmos Features

    The following describes each item of this menu. Date The date format is: Day : Sun to Sat Month : 1 to 12 Date : 1 to 31 Year : 1999 to 2099 _____________________________________________________________________ Cybernet iOne-Medical PC BIOS Setup Page 15...
  • Page 26 (HD > 528MB and supports Logical Block Addressing) Large (for MS-DOS only) Auto Remarks: The main board supports one serial ATA ports and are represented in this setting as IDE Channel 2. _____________________________________________________________________ BIOS Setup Cybernet iOne-Medical PC Page 16...
  • Page 27 The system boot will not be halted for any error that may be detected. All, But Keyboard The system boot will not be halted for a keyboard error; it will stop for all other errors _____________________________________________________________________ Cybernet iOne-Medical PC BIOS Setup Page 17...
  • Page 28: Advanced Bios Features

    DRAM (system memory). CPUs from 486-type on up contain internal cache memory, and most, but not all, modern PCs have additional (external) cache memory. When the CPU requests data, the system transfers the requested data from the main DRAM _____________________________________________________________________ BIOS Setup Cybernet iOne-Medical PC Page 18...
  • Page 29 By default, this field is set to Disabled. Typematic Rate (Chars/Sec) When the typematic rate is enabled, the system registers repeated keystrokes speeds. Settings are from 6 to 30 characters per second. _____________________________________________________________________ Cybernet iOne-Medical PC BIOS Setup Page 19...
  • Page 30: Security Option

    Win95/98. Small Logo (EPA) Show The EPA logo appears at the right side of the monitor screen when the system is boot up. The default setting is Disabled . _____________________________________________________________________ BIOS Setup Cybernet iOne-Medical PC Page 20...
  • Page 31: Advanced Chipset Features

    The fields under the VGA Setting and their default settings are: PEG/On Chip VGA Control: Onchip VGA On-Chip Frame Buffer Size: 8MB DVMT Mode: DVMT DVMT/Fixed Memory Size: 128MB Boot Display: Auto Panel Scaling: Auto Panel Number: 4 _____________________________________________________________________ Cybernet iOne-Medical PC BIOS Setup Page 21...
  • Page 32: Integrated Peripherals

    PATA IDE Mode (Secondary) and SATA Port (PO, P2 is Primary). OnChip Primary/Secondary PCI IDE The integrated peripheral controller contains an IDE interface with support for two IDE channels. Select Enabled to activate each channel separately. _____________________________________________________________________ BIOS Setup Cybernet iOne-Medical PC Page 22...
  • Page 33: Usb Device Setting

    Please update your system to Windows 2000 SP4 or Windows XP SP2. USB Operation Mode The options for this field are Full/Low speed and High speed . By default, this field is set to High speed . _____________________________________________________________________ Cybernet iOne-Medical PC BIOS Setup Page 23...
  • Page 34 The options for this field are Enabled and Disabled . By default, this field is set to Enabled . USB Storage Function The options for this field are Enabled and Disabled . By default, this field is set to Enabled . _____________________________________________________________________ BIOS Setup Cybernet iOne-Medical PC Page 24...
  • Page 35: Power Management Setup

    Enable this function to support ACPI (Advance Configuration and Power Interface). ACPI Suspend The default setting of the ACPI Suspend mode is S3(STR) . RUN VGABIOS if S3 Resume The default setting of this field is Auto . _____________________________________________________________________ Cybernet iOne-Medical PC BIOS Setup Page 25...
  • Page 36 CPU will be shut off. By default, the setting is Disabled . HDD Power Down When enabled, and after the set time of system inactivity, the hard disk drive will be powered down while all other devices remain active. _____________________________________________________________________ BIOS Setup Cybernet iOne-Medical PC Page 26...
  • Page 37 IRQ to occur. When the operating system is ready to respond to the request, it interrupts itself and performs the service. _____________________________________________________________________ Cybernet iOne-Medical PC BIOS Setup Page 27...
  • Page 38: Init Display First

    MPEG ISA/VESA VGA card. When this field is disabled, a PCI/VGA cannot work with an MPEG ISA/VESA card. Maximum Payload Size The default setting of the PCI Express Maximum Payload Size is 128. _____________________________________________________________________ BIOS Setup Cybernet iOne-Medical PC Page 28...
  • Page 39: Pc Health Status

    This field allows the user to set the temperature so that when the temperature is reached, the system sounds a warning. This function can help prevent damage to the system that is caused by overheating. _____________________________________________________________________ Cybernet iOne-Medical PC BIOS Setup Page 29...
  • Page 40: Load Optimized Defaults

    Select this option to exit the Setup utility without saving the changes you have made in this session. Typing “Y” will quit the Setup utility without saving the modifications. Typing “N” will return you to Setup utility. _____________________________________________________________________ BIOS Setup Cybernet iOne-Medical PC Page 30...
  • Page 41: Appendix

    /* DATA[0] = GPO1, DATA[1] = GPO2, ……, DATA[7] = GPO8 */ read GPI main() int DATA; init_gpio(); DATA = read_gpi(); /* DATA[0] = GPI1, DATA[1] = GPI2, ……, DATA[7] = GPI8 */ _____________________________________________________________________ Cybernet iOne-Medical PC Appendix...
  • Page 42: Vesa Mounting

    1. The wall-mounting attachment is comprised of two parts: one back bracket, and one mounting bracket. 2. First attach the back bracket to the rear cover of the iOne-MP171, securing it in place with four of the Phillips-head screws provided.
  • Page 43 Screws: M4 x 8mm Figure D.1: VESA mounting dimension diagram (75 x 75 mm, 100 x 100 mm) ____________________________________________________________________ Cybernet iOne-Medical PC Appendix...
  • Page 44: Scrap Computer Recycling

    For the computers that are no longer useful or work well, please contact with worldwide distributors for recycling. The worldwide distributors show on the following website: http://www.cybernetman.com/ Note: Follow the national requirement to dispose unit _____________________________________________________________________ Appendix Cybernet iOne-Medical PC...

Table of Contents