Version Change History Date Version Description Remark 11/08/2016 First release Steven Huang CyberMed M156S User’s Manual...
Page 3
Intel is a trademark or registered trademark of Intel Corporation. Microsoft Windows is a registered trademark of Microsoft Corporation. Winbond is a registered trademark of Winbond Electronics Corporation. All other product names or trademarks are properties of their respective owners. CyberMed M156S User’s Manual...
Page 4
To avoid risk of electric shock, this equipment must only be connected to a supply mains with protective earth. Do not modify this equipment without authorization of the manufacturer. CyberMed M156S User’s Manual...
Page 5
Safety Instructions Intended use The CyberMed M156S is intended to serve as a medical monitor which is designed for general purpose for hospital environment. It shall not be used for life-supporting system. Intended User profile The equipment is intended for infant or adults by profession Health care professionals.
Page 6
2. Unless proper ventilation is present, do not place unit in an enclosed area; such as a built-in shelf. Keep a minimum distance of 10 cm between the display unit and wall. CyberMed M156S User’s Manual...
Page 7
5. When replacement parts are needed for the medical panel PC unit, make sure service technicians use replacement parts specified by the manufacturer, or those with the same characteristics and performance as the original parts. If unauthorized parts are used it may result in starting a fire, electrical shock and/or other dangers. CyberMed M156S User’s Manual...
Page 8
IEC 60601-1-1. The unit is for exclusive interconnection with IEC 60601-1 certified equipment in the patient environment and IEC 60XXX certified equipment outside of the patient environment. If in doubt, consult the technical services department or your local representative. viii CyberMed M156S User’s Manual...
Page 9
B) Use a power cord that matches the voltage of the power outlet, which has been approved and complies with the safety standard of your particular country. C) Caution: This adapter Sinpro HPU101-105 is a forming part of the medical device Contact information: Cybernet Manufacturing, Inc. 5 Holland Irvine, CA92618, USA Free: (888)-834-4577 Phone: (949)-600-8000 Fax: (949)-600-8013 CyberMed M156S User’s Manual...
System Set Up…………………………………………………………………………………………………..10 Dimension……………………………………………………………………………………………………….11 System View…………………………………………………………………………………………………….12 Disconnect Device……………………………………………………………………………………………..14 BIOS Setup…………………………………………………………………………………………………15 Appendix…………………………………………………………………………………………………..23 A. Jumper settings and Connectors………………………………………………………………………………23 B. Battery Pack Specifications (optional kit)…………………………………………………………………..39 C. How to disable battery when system hang up ………………………………………………………………..39 D. Cybernet e-recycling SOP…………………………………………………………………………………….40 CyberMed M156S User’s Manual...
The CyberMed M156S includes all the features of a powerful computer into a slim and attractive chassis with a 15.6” wide screen 400nits TFT display with 1366 x 768 resolutions. Integrating with high brightness LCD is easier to analyze DICOM image.
Package list Before you begin installing your Medical Station, please make sure that the following items have been shipped: The CyberMed M156S Medical Panel PC unit User's manual, chipset drivers Power Adapter x 1 (Mf:Sinpro, type/model: HPU101-105) ...
Easy clean full flat 5 wire resistive touch screen (customized order configuration) USB/LAN/COM isolated module by different configuration (optional order configuration) Optional WLAN/Bluetooth module with inner antenna, battery pack, web camera, desktop stand and project with RFID solution CyberMed M156S User’s Manual...
Power Adapter Specifications Power Close-frame Sinpro Type HPU101-105 Input Rating AC 100 ~ 240 V, 1.2 – 0.5A @ 47 ~ 63 Hz Output Rating DC 12V, 8.33A MTBF 100,000 hrs operation at 25°C CyberMed M156S User’s Manual...
Page 15
Fanless Touch Screen Type Full flat projective capacitive touch panel Interface Controller with USB interface, 5V Resolution 100ppi to 25ppi Based WIN7 definition ppi (Pixel per inch) Light Transmission 90% ± 3% Life Time 100M times CyberMed M156S User’s Manual...
Guidance and manufacturer’s declaration – electromagnetic emissions The model CyberMed M156S is intended for use in the electromagnetic environment specified below. The customer or the user of the model CyberMed M156S should assure that it is used in such an environment.
Guidance and manufacturer’s declaration – electromagnetic immunity The model CyberMed M156S is intended for use in the electromagnetic environment specified below. The customer or the user of the model CyberMed M156S should assure that it is used in such an environment.
Page 18
RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the model CyberMed M156S is used exceeds the applicable RF compliance level above, the model CyberMed M156S should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as reorienting or relocating the model CyberMed M156S.
Do not immerse or rinse the CyberMed M156S and its peripherals. If you accidentally spill liquid on the device, disconnect the unit from the power source. Contact your Biomed regarding the continued safety of the unit before placing it back in operation.
“F11” key, go into BIOS quick boot menu, select “USB-CD ROM”, WAIT FOR 20 SECONDS, then press enter, system OS will boot up from USB-CD/DVD drive directly. Notice: The installation is only to be carried out by manufacturer trained and authorized personnel. CyberMed M156S User’s Manual...
7. LCD on/off (with LED status indicator: LCD ON: dark, LCD OFF: Amber) 8. Clean me (with LED status indicator: ON: Amber, OFF: dark) a. Keep on contacting 5 seconds to active b. keep contacting 5 seconds to release c. auto release after 60 seconds CyberMed M156S User’s Manual...
Page 23
I/O parts Isolated I/O parts CyberMed M156S User’s Manual...
Unplug the power cord from the power adapter jack to disconnect the device. Turn off the system: Turning off CyberMed M156S properly is important for system reliability. 1. On the start menu, click “Shut down” and select “OK” CyberMed M156S User’s Manual...
In general, you press the arrow keys to highlight items, <Enter> to select, the <PgUp> and <PgDn> keys to change entries, <F1> for help and <Esc> to quit. When you enter the Setup utility, the Main Menu screen will appear on the screen. The Main Menu allows you to select from various setup functions and exit choices. CyberMed M156S User’s Manual...
Page 26
Security Device. TCG EFI protocol and INT1A interface will not be available. ACPI Settings Enable Hibernation Enables or Disables System ability to Hibernate (0S/S4 Sleep State). This option may be not effective with some OS. ACPI Sleep State CyberMed M156S User’s Manual...
Page 27
DynamicTime , System will wake on the current time + Increase minute(s). CPU Configuration Socket 0 CPU Information Socket specific CPU Information. IDE Configuration Serial-ATA (SATA) Enable / disable Serial ATA. SATA Test Mode Test Mode enable / disable. SATA Speed Support CyberMed M156S User’s Manual...
Page 28
Enable / Disable webcam key. Fn key Enable/Disable Function key Miscellaneous Configuration PCI Express Dynamic Clock Gating Enable / Disable PCIE Dynamic Clock Gating. Show/hide hidden items For debug only. Show / hide hidden items. Info Report Configuration Post Report CyberMed M156S User’s Manual...
Page 29
Disabled = Azalia will be unconditionally disabled. Enable = Azalia will be unconditionally Enabled. Auto = Azalia will be enabled if present disabled otherwise. Restore AC Power Loss Select AC power state when power is re-applied after a power failure. CyberMed M156S User’s Manual...
Page 30
Setup Prompt Timeout Number of seconds to wait for setup activation key. 65535(0xFFFF) means indefinite waiting. Bootup Numlock State Selects the keyboard NumLock state. PXE Boot PXE Network Boot Enable / Disable. OS Selection OS Selection. CyberMed M156S User’s Manual...
Page 31
Restore the User Defaults to all the setup options. Boot Override To override the boot device. Launch EFI Shell From filesystem device Attempts to Launch EFI Shell application (Shell.efi) from one of the available filesystem devices. CyberMed M156S User’s Manual...
Page 32
Reset System with ME disable ModeMEUD000 ME will runs into the temporary disable mode, Ignore if ME Ignition FWMEUD001. CyberMed M156S User’s Manual...
Note: Some of jumpers or connectors will be removed base on system configuration. Jumper and Connector Definition Block JP1 – Touch Panel Type Selection Description Jumper Setting 3M type 1-2, 3-4 (default) ELO type 5-6,7-8 JP2 – LVDS Power Selection Description Jumper Setting CyberMed M156S User’s Manual...
Page 35
JP5 – Panel Type Selection GPIO3 JP5(1-2) short JP5(1-2) open GPIO2 JP5(3-4) short JP5(3-4) open GPIO1 JP5(5-6) short JP5(5-6) open GPIO0 JP5(7-8) short JP5(7-8) open JP6 – CMOS Clear Description Jumper Setting Normal Open 1-2 (default) CyberMed M156S User’s Manual...
Page 36
APPENDIX CMOS Clear JP8,JP9 – Support Y cable with DVI+VGA Description Jumper Setting Description Open DVI+VGA Short DVI+VGA JP10 – COM4 Power Selection Description Jumper Setting +5VS 2-3(default) +12VS CyberMed M156S User’s Manual...
Page 44
232_RI# +5VS / +12VS J31 – Internal COM4 TTL Pin # Signal Description Pin # Signal Description DCD# DSR# RTS# SOUT CTS# DTR# +5VS J32 – External USB 3.0 Port Pin # Signal Description Data- Data+ CyberMed M156S User’s Manual...
Page 45
ROUT- LOUT- J34 –External RJ45 Ethernet Port Pin # Signal Description Data0+ Data0- Data1+ Data2+ Data2- Data1- Data3+ Data3- J35 – Power Switch connect Pin # Signal Description Power ON J36,J37,J38 – External USB 2.0 Port CyberMed M156S User’s Manual...
Page 46
J40 / J41 – External Audio Phone Jack Pin # Signal Description Line Out (stereo) Green Microphone (stereo) Pink J43 – Internal COM3 Serial Port Pin # Signal Description Pin # Signal Description 232_DCD# 232_DSR# 232_SIN 232_RTS# 232_SOUT 232_CTS# 232_DTR# 232_RI# +5VS CyberMed M156S User’s Manual...
Page 47
Pin # RS-232 RS-422 RS-485 Carrier Detect Transmit Data - Transmit Data - Receive Data Transmit Data + Transmit Data + Transmit Data Receive Data + Data Terminal Ready Receive Data - Ground Data Set Ready CyberMed M156S User’s Manual...
Page 48
APPENDIX Request to Send Clear to Send Ring Indicator CyberMed M156S User’s Manual...
2. Remove AC power cord, then the battery LED will on. 3. Press volume up key 10 seconds, then all LED will turn on and turn off 4. Plug in AC power cord again, press power button then you can power on system. CyberMed M156S User’s Manual...
APPENDIX D. Cybernet e-recycling SOP Cybernet has an e-recycling programthat is very easy to use. Just follow the steps explained below or go to our website at www.cybernet.us 1. Request a RMA via phone, email or support request. 2. We will arrange a call tag to have the product pickup. Just have it packed and ready to ship.