System Event; Figure 39 ─ Video Loss Actions Setup Screen; Figure 40 ─ Health Check Setup Screen - ADT 4-channel DVR User Manual

Hide thumbs Also See for 4-channel DVR:
Table of Contents

Advertisement

User's Manual
Highlight the Actions tab, and the Video Loss Actions setup screen appears.
Figure 39 ─ Video Loss Actions setup screen.
Highlight the box under the Alarm-Out heading and press the
internal buzzer) that you would like to activate and to sound whenever the DVR detects video loss on the selected camera.
NOTE: For the Alarm-Out action, the alarm output and beep you select should be set to the Event mode in the
Alarm-Out setup screen (Schedule tab).
Highlight the box under the Notify heading and press the
Notification and pressing the
button. Highlight OK and press the
pressing the
NOTE: For the Notify action, the notify item you select should be enabled in the Notification setup screen and
the DVR should be registered in the RAS (Remote Administration System).
Highlight the desired box under the PTZ heading, and press the
preset position for each PTZ camera, where you want PTZ cameras to move to when the DVR detects video loss on
the selected camera's input.

System Event

Highlight System Event in the Event menu and press the
Figure 40 ─ Health Check setup screen.
28
button. You can toggle the individual items On and Off by highlighting that item and
button to accept your changes.
The DVR can be set to react to video loss differently for each
camera. Each camera can be associated with another camera,
trigger an Alarm-Out connector, sound the DVR's internal
buzzer, notify a number of different devices, and/or move PTZ
cameras to preset positions.
Highlight the box under the Record heading and press the
button. A list of cameras appears. You can associate as many
cameras with that camera as you wish. If the DVR detects
video loss on the selected camera, it starts recording video
from all the associated cameras.
NOTE: For the Record action, the camera you select
should be set to the Event or Time & Event recording mode
in the Record Schedule setup screen.
button. Select between Alarm Output and Beep (DVR's
button. You can toggle the entire list On and Off by highlighting
button. A list of PTZ presets appear. Select the
button. The System Event setup screen appears.
The DVR can be configured to run self-diagnostics and report
the results.
Highlighting the box beside System and pressing the
allows you to select the interval that you want the DVR to run
self-diagnostics on the system. You can select from 1 hr. to
30 days or Never.
button