Cely PS-50 Series User Manual

Cely PS-50 Series User Manual

Only weight scales

Advertisement

User's Manual
Ref.: 49-MCEPS56EN03 Rev.: 03
PS-50/60
ONLY WEIGHT SCALES

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PS-50 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Cely PS-50 Series

  • Page 1 User’s Manual Ref.: 49-MCEPS56EN03 Rev.: 03 PS-50/60 ONLY WEIGHT SCALES...
  • Page 3: Table Of Contents

    CONTENTS INTRODUCTION ..............................1 SPECIFICATIONS ..............................1 INSTALLATION..............................1 3.1. GENERAL INSTALLATION..........................1 3.2. INSTALLATION OF SERIES PS-50/60 ......................2 DESCRIPTION OF KEYS ............................2 DISPLAY................................... 2 OPERATION ................................2 6.1. MANUAL ZERO SETTING..........................2 6.2. SETTING THE TARE............................2 6.3.
  • Page 5: Introduction

    90/384/CE, therefore they are not valid for commercial transactions The series PS-50/60 offers a precise, rapid and versatile only-weight scales for all uses. There are 3 weighing scales models in this range. The platform size is 190mm x 230mm, and the capacity ranges from 3 kg to 15 kg.
  • Page 6: Installation Of Series Ps-50/60

    Series PS-50/60 3.2. INSTALLATION OF SERIES PS-50/60 Weighing scales series PS-50/60 uses an AC/DC voltage adapter and can also be used with a rechargeable battery. Please check that the power supply voltage matches that stated on the adapter. The socket for the voltage adapter is situated under the scales.
  • Page 7: Change Unit Of Weight

    Series PS-50/60 When the packaging is removed, a negative value will be shown. If the scales are tared before the packaging is removed, this value will be the gross weight of the packaging plus all the product that was removed. the zero indicator will also light up because the platform returns to the same situation as when pressed.
  • Page 8: Setting The Secondary Unit

    Series PS-50/60 7.6. SETTING THE SECONDARY UNIT After entering Configuration mode, the display will show “F0 CAL”. Press four times and the display will show “F4 unt”. Press to enter, then press to change the secondary weighing unit. Press simultaneously to exit.
  • Page 9: Battery Operation

    Series PS-50/60 8. BATTERY OPERATION The weight indicator can operate with batteries if required. The battery will last approximately 100 hours. When the battery needs recharging, the symbol BAT LO is shown on the indicator. The battery must be recharged when this symbol appears. The scales will continue to work for about 10 hours and then they will shut down automatically to protect the battery.
  • Page 10: Error Codes

    ERROR DESCRIPTION SOLUTION CODES Remove the weight from the scales. If the problem continues, contact your distributor or CELY Above the range - -OL - for assistance. The scales were not correctly set-up in the zero range, or they were switched on when was pressed Remove the weight from the scales and try again.
  • Page 11 Series PS-50/60 DECLARATION OF CONFORMITY CELY Manufacturer Type: PS-50/60 Series The aforementioned manufacturer declares that the apparatus described herein complies with the requirements contained in Directive 89/336/CEE and 73/23/CEE and, where applicable, to the following harmonised regulations: EN55022 Class B...