Lennox XP14 SERIES Unit Information page 19

Xp14 series high efficiency residential split system heat pump unit
Table of Contents

Advertisement

Use
cooling
mode
60ºF (15ºC)
Use
heating
mode
SATº
LIQº –
SCº
=
Subcool Target
INDOOR
HEAT
Cooling Heating
MATCH−UP
PUMP
(+5ºF)
(+1ºF)
XP14−018
CBX27UH−018/024
13
CBX32MV−018/024
15
XP14−024
CH23−41
16
CBX26UH−024
25
CBX27UH−018/024
15
CBX32M−018/024
16
CBX32M−030
15
CBX32MV−018/024
16
CBX32MV−024/030
15
CH33−42B
14
CH33−36A
16
CH33−36C
16
CR33−30/36A/B/C
25
CX34−25A/B
16
CX34−31A/B
15
CX34−36A/B/C
16
CX34−38A/B
14
XP14−030
CH23−41
11
CH23−51
6
CBX26UH−024
30
CBX26UH−030
29
CBX27UH−030
11
CBX32M−030
11
CBX32M−036
11
CBX32MV−024/030
11
CBX32MV−036
11
C33−44C
11
CH33−36C
11
CH33−42B
6
CR33−30/36A/B/C
30
*Add charge = Extra match−up amount required in addition to charge indicated on Heat Pump nameplate (remember to also add any charge required for line set differ-
ences from 15 feet).
Adding Charge per Indoor Unit Match using Subcooling Method
1 Check the airflow as illustrated in figure20 to be sure the indoor airflow is as required.
(Make any air flow adjustments before continuing with the following procedure.)
2 Measure outdoor ambient temperature; determine whether to use cooling mode or
heating mode to check charge.
3 Connect gauge set.
4 Check Liquid and Vapor line pressures. Compare pressures with Normal Operating
Pressures table 5, (Table 5 is a general guide. Expect minor pressure variations.
Significant differences may mean improper charge or other system problem.)
5 Set thermostat for heat/cool demand, depending on mode being used:
When the outdoor ambient temperature is 60°F (15°C) and above.
Using cooling mode
Target subcooling values in table below are based on 70 to 80°F (21−27°C) indoor return
air temperature; if necessary, operate heating to reach that temperature range; then set
thermostat to cooling mode setpoint to 68ºF (20ºC). When pressures have stabilized,
continue with step 6.
When the outdoor ambient temperature is below 60°F (15°C).
Using heating mode
Target subcooling values in table below are based on 65−75°F (18−24°C) indoor return air
temperature; if necessary, operate cooling to reach that temperature range; then set
thermostat to heating mode setpoint to 77ºF (25ºC). When pressures have stabilized,
continue with step 6.
6 Read the liquid line temperature; record in the LIQº space.
7 Read the liquid line pressure; then find its corresponding temperature in the temperature/
pressure chart listed on page 20 and record it in the SATº space.
8 Subtract LIQº temp. from SATº temp. to determine subcooling; record it in SCº space.
9 Compare SCº results with table below, being sure to note any additional charge for line
set and/or match−up.
10 If subcooling value is greater than shown in table, remove refrigerant; if less than shown,
add refrigerant.
11 If refrigerant is added or removed, repeat steps 5 through 10 to verify charge.
*Add
INDOOR
charge
MATCH−UP
lb
oz
XP14−030 (cont'd)
7
0
8
CX34−31A/B
7
0
0
CX34−38A/B
lb
oz
CX34−43B/C
XP14−036
8
0
2
7
0
0
CBX26UH−036
8
1
2
CBX26UH−037
8
0
14
CBX27UH−036
8
1
3
CBX32M−036
8
0
14
CBX32M−042
8
1
2
CBX32MV−036
11
1
10
CBX32MV−048
8
1
0
C33−44C
8
0
4
CH33−50/60C
7
0
2
CH33−44B
8
0
14
CH33−48B
8
1
3
CR33−50/60C
8
1
8
CR33−48B/C
11
2
2
CX34−49C
lb
oz
CX34−43B/C, −50/60C
6
0
8
CX34−38A/B, −44/48C
XP14−042
6
1
12
8
0
6
CH23−68
8
2
3
CBX26UH−042
6
2
4
CBX27UH−042
6
1
6
CBX32M−048
6
2
4
CBX32MV−048
6
1
6
CH33−62D
6
2
4
CH33−50/60C
6
2
3
CH33−60D
3
0
0
CR33−50/60C,−60D
6
1
12
CBX33−042,−048
8
0
8
CBX33−060
TABLE 7
Subcool Target
HEAT
*Add
Cooling Heating
PUMP
charge
(+5ºF)
(+1ºF)
lb
oz
11
6
1
6
11
6
2
3
15
11
2
14
lb
oz
26
5
0
0
25
4
1
9
13
6
0
3
13
6
0
2
13
6
0
3
13
6
0
3
11
8
2
5
13
6
0
0
11
8
2
5
13
6
1
7
13
6
1
8
25
4
1
15
25
5
0
9
13
6
2
4
13
6
1
8
13
6
0
0
lb
oz
20
9
0
13
27
6
0
0
12
6
0
8
12
6
0
7
12
6
0
8
12
6
0
10
12
6
0
7
12
6
0
4
26
6
0
4
12
7
0
4
12
6
0
7
Page 19
Subcool Target
INDOOR
HEAT
Cooling Heating
MATCH−UP
PUMP
(+5ºF)
(+1ºF)
XP14−042 (cont'd)
CX34−62C, −62D
12
CX34−49C
12
CX34−60D
12
XP14−048
CH23−68
20
CBX26UH−048
8
CBX27UH−048
11
CBX32M−048, −060
11
CBX32MV−048, −060
11
CBX32MV−068
10
CH33−50/60C
11
CH33−62D
10
CH33−60D
11
CR33−50/60C
35
CR33−60D
37
CBX33−048, −060
12
CX34−62C, −62D
10
CX34−49D
11
CX34−60D
11
XP14−060
CH23−68
12
CBX26UH−048
12
CBX26UH−060
14
CBX27UH−060
12
CBX32M−048, −060
12
CBX32MV−048, −060
12
CBX32MV−068
12
CH33−50/60C
12
CH33−62D
12
CBX33−060
12
CX34−62C, −62D
12
*Add
charge
lb
oz
6
0
9
6
0
7
6
0
4
lb
oz
9
2
9
7
1
9
8
1
2
8
1
2
8
1
2
7
1
12
8
1
1
7
1
14
8
0
0
5
0
0
6
0
0
8
1
2
7
1
7
8
0
14
8
0
0
lb
oz
5
0
0
7
1
0
4
0
0
5
0
0
5
0
0
5
0
0
7
1
0
5
0
0
5
0
0
8
0
0
7
1
0