Use
cooling
mode
60ºF (15ºC)
Use
heating
mode
SATº
LIQº –
SCº
=
Subcool Target
INDOOR
HEAT
Cooling Heating
MATCH−UP
PUMP
(+5ºF)
(+1ºF)
XP14−018
CBX27UH−018/024
13
CBX32MV−018/024
15
XP14−024
CH23−41
16
CBX26UH−024
25
CBX27UH−018/024
15
CBX32M−018/024
16
CBX32M−030
15
CBX32MV−018/024
16
CBX32MV−024/030
15
CH33−42B
14
CH33−36A
16
CH33−36C
16
CR33−30/36A/B/C
25
CX34−25A/B
16
CX34−31A/B
15
CX34−36A/B/C
16
CX34−38A/B
14
XP14−030
CH23−41
11
CH23−51
6
CBX26UH−024
30
CBX26UH−030
29
CBX27UH−030
11
CBX32M−030
11
CBX32M−036
11
CBX32MV−024/030
11
CBX32MV−036
11
C33−44C
11
CH33−36C
11
CH33−42B
6
CR33−30/36A/B/C
30
*Add charge = Extra match−up amount required in addition to charge indicated on Heat Pump nameplate (remember to also add any charge required for line set differ-
ences from 15 feet).
Adding Charge per Indoor Unit Match using Subcooling Method
1 Check the airflow as illustrated in figure20 to be sure the indoor airflow is as required.
(Make any air flow adjustments before continuing with the following procedure.)
2 Measure outdoor ambient temperature; determine whether to use cooling mode or
heating mode to check charge.
3 Connect gauge set.
4 Check Liquid and Vapor line pressures. Compare pressures with Normal Operating
Pressures table 5, (Table 5 is a general guide. Expect minor pressure variations.
Significant differences may mean improper charge or other system problem.)
5 Set thermostat for heat/cool demand, depending on mode being used:
When the outdoor ambient temperature is 60°F (15°C) and above.
Using cooling mode
Target subcooling values in table below are based on 70 to 80°F (21−27°C) indoor return
air temperature; if necessary, operate heating to reach that temperature range; then set
thermostat to cooling mode setpoint to 68ºF (20ºC). When pressures have stabilized,
continue with step 6.
When the outdoor ambient temperature is below 60°F (15°C).
Using heating mode
Target subcooling values in table below are based on 65−75°F (18−24°C) indoor return air
temperature; if necessary, operate cooling to reach that temperature range; then set
thermostat to heating mode setpoint to 77ºF (25ºC). When pressures have stabilized,
continue with step 6.
6 Read the liquid line temperature; record in the LIQº space.
7 Read the liquid line pressure; then find its corresponding temperature in the temperature/
pressure chart listed on page 20 and record it in the SATº space.
8 Subtract LIQº temp. from SATº temp. to determine subcooling; record it in SCº space.
9 Compare SCº results with table below, being sure to note any additional charge for line
set and/or match−up.
10 If subcooling value is greater than shown in table, remove refrigerant; if less than shown,
add refrigerant.
11 If refrigerant is added or removed, repeat steps 5 through 10 to verify charge.
*Add
INDOOR
charge
MATCH−UP
lb
oz
XP14−030 (cont'd)
7
0
8
CX34−31A/B
7
0
0
CX34−38A/B
lb
oz
CX34−43B/C
XP14−036
8
0
2
7
0
0
CBX26UH−036
8
1
2
CBX26UH−037
8
0
14
CBX27UH−036
8
1
3
CBX32M−036
8
0
14
CBX32M−042
8
1
2
CBX32MV−036
11
1
10
CBX32MV−048
8
1
0
C33−44C
8
0
4
CH33−50/60C
7
0
2
CH33−44B
8
0
14
CH33−48B
8
1
3
CR33−50/60C
8
1
8
CR33−48B/C
11
2
2
CX34−49C
lb
oz
CX34−43B/C, −50/60C
6
0
8
CX34−38A/B, −44/48C
XP14−042
6
1
12
8
0
6
CH23−68
8
2
3
CBX26UH−042
6
2
4
CBX27UH−042
6
1
6
CBX32M−048
6
2
4
CBX32MV−048
6
1
6
CH33−62D
6
2
4
CH33−50/60C
6
2
3
CH33−60D
3
0
0
CR33−50/60C,−60D
6
1
12
CBX33−042,−048
8
0
8
CBX33−060
TABLE 7
Subcool Target
HEAT
*Add
Cooling Heating
PUMP
charge
(+5ºF)
(+1ºF)
lb
oz
11
6
1
6
11
6
2
3
15
11
2
14
lb
oz
26
5
0
0
25
4
1
9
13
6
0
3
13
6
0
2
13
6
0
3
13
6
0
3
11
8
2
5
13
6
0
0
11
8
2
5
13
6
1
7
13
6
1
8
25
4
1
15
25
5
0
9
13
6
2
4
13
6
1
8
13
6
0
0
lb
oz
20
9
0
13
27
6
0
0
12
6
0
8
12
6
0
7
12
6
0
8
12
6
0
10
12
6
0
7
12
6
0
4
26
6
0
4
12
7
0
4
12
6
0
7
Page 19
Subcool Target
INDOOR
HEAT
Cooling Heating
MATCH−UP
PUMP
(+5ºF)
(+1ºF)
XP14−042 (cont'd)
CX34−62C, −62D
12
CX34−49C
12
CX34−60D
12
XP14−048
CH23−68
20
CBX26UH−048
8
CBX27UH−048
11
CBX32M−048, −060
11
CBX32MV−048, −060
11
CBX32MV−068
10
CH33−50/60C
11
CH33−62D
10
CH33−60D
11
CR33−50/60C
35
CR33−60D
37
CBX33−048, −060
12
CX34−62C, −62D
10
CX34−49D
11
CX34−60D
11
XP14−060
CH23−68
12
CBX26UH−048
12
CBX26UH−060
14
CBX27UH−060
12
CBX32M−048, −060
12
CBX32MV−048, −060
12
CBX32MV−068
12
CH33−50/60C
12
CH33−62D
12
CBX33−060
12
CX34−62C, −62D
12
*Add
charge
lb
oz
6
0
9
6
0
7
6
0
4
lb
oz
9
2
9
7
1
9
8
1
2
8
1
2
8
1
2
7
1
12
8
1
1
7
1
14
8
0
0
5
0
0
6
0
0
8
1
2
7
1
7
8
0
14
8
0
0
lb
oz
5
0
0
7
1
0
4
0
0
5
0
0
5
0
0
5
0
0
7
1
0
5
0
0
5
0
0
8
0
0
7
1
0