PROBLEM
Compressor is not
supplying enough
air to operate
accessories.
Motor will not run. Fuse blown, circuit breaker
CAUSE
Prolonged excessive use of
air.
Compressor is not large
enough for air requirement.
Hole in hose.
Air leaks.
tripped.
Extension cord is wrong
length or gauge.
Loose electrical connections.
Faulty motor.
19 - ENG
CORRECTION
Decrease amount of air
usage.
Check the accessory
air requirement. If it is
higher than the SCFM
or pressure supplied by
your air compressor,
you need a larger com-
pressor.
Check and replace if
required.
Tighten any exposed
fittings.
Check fuse box for
blown fuse and replace
as necessary. Reset cir-
cuit breaker. Do not use
a fuse or circuit breaker
with higher rating than
that specified for your
particular branch circuit.
Check for proper fuse.
You should use a time
delay fuse.
Check for low voltage
problem.
Check the extension
cord.
Disconnect the other
electrical appliances
from circuit or operate
the compressor on its
own branch circuit.
Check the extension
cord.
Check wiring connection
inside terminal box.
Have checked by a
Trained Service
Technician.