Mounting the Water Heater
Before locating the position for
installation of the water heater, make sure
that there is sufficient clearance between
the ceiling and the side wall.
vertically, with water connection at the
bottom.
Figure 6
Ceiling
water heater
to drill 2 holes at least 90 mm deep in
the wall (Fig. 8 : Step 3). The two holes
should be aligned horizontally. The
horizontal distance between the 2 holes
should be 73.6 mm (Fig. 8 : Step 2).
Figure 8
1
2
Drilling
Tool
Wall
3
90 mm
Concrete
Hole
Wall
7
3-1/2 ft. (approx.) from a grounded
230V electrical outlet.
Make sure that the wall can withstand
at least twice the weight of the water
heater when completely filled with
water.
Figure 7
Solid
Concrete
Wall
holes (Fig. 9 : Step 1).
expansion anchors and tighten the
Hanging Screws by rotating it till it gets
fixed steadily (Fig. 9 : Step 2).
Figure 9
1
Concrete
Wall
2
Concrete
Wall
False
Wall
Expansion
Anchors
Hole
Hanging
Screws