9.3. Calibrating the marker sensor for material with gaps:
The TP343 is set up both for endless application (markingSTRIP) and for the application
of material with gaps (labels) or material with markers (WireMarker 211-111 or -121).
If the red TP343 lamp flashes during printing, despite having the correct driver settings
and is not exhibiting a fault that is outlined in the table above, then recalibrate the materi-
al.
Switch the unit off to change over to material with gaps.
With the unit off, press and hold the FEED BUTTON.
Switch the unit on and wait for the following color combination:
1x green
1x yellow
5x red
Then release the FEED button. The printer will pull approximately 20 markers through in
order to correctly adjust the marker sensor. After this, it should be possible to output label-
by-label with the FEED button.
Restart the print job, it should output correctly.
Please contact the ProSERVE with any remaining questions!