Model
VFDR(18,24,30)LB
VFDR18LB10
VFDT(18,24,30)LB
VFDM(18,24,30)LB

WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM HEATERS

Water vapor is a by-product of gas combustion. An unvented room
heater produces approximately one (1) ounce (30ml) of water for
every 1,000 BTU's (.3KW's) of gas input per hour.
Unvented room heaters must be used as supplemental heat (a
room) rather than a primary heat source (an entire house). In most
supplemental heat applications, the water vapor does not create a
problem. In most applications, the water vapor enhances the low
humidity atmosphere experienced during cold weather.
Page 6
PRODUCT SPECIFICATIONS
Gas
Valve Type
Natural
Millivolt
Propane
Natural
Millivolt
Propane
Natural
Thermostat
Propane
Natural
Manual
Propane
Model
BTU/hr.
Max. Rate
VFDR18LB10N
10,000
VFDR18LB10P
10,000
VFDR18LBN
28,000
VFDR18LBP
28,000
VFDR24LBN
34,000
VFDR24LBP
34,000
VFDR30LBN
40,000
VFDR30LBP
40,000
VFDT18LBN
28,000
VFDT18LBP
28,000
VFDT24LBN
34,000
VFDT24LBP
34,000
VFDT30LBN
40,000
VFDT30LBP
40,000
VFDM18LBN
28,000
VFDM18LBP
28,000
VFDM24LBN
34,000
VFDM24LBP
34,000
VFDM30LBN
40,000
VFDM30LBP
40,000
Regulator Pressure
Gas Inlet Pressure
Setting
3.5" W.C.
10.0" W.C.
3.5" W.C.
10.0" W.C.
6.0" W.C.
10.0" W.C.
6.0" W.C.
10.0" W.C.
BTU/hr.
Med. Rate
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
23,000
25,000
29,000
30,000
32,000
36,000
The following steps will help insure that water vapor does not
become a problem.
1. Be sure the heater is sized properly for the application, including
ample combustion air and circulation air.
2. If high humidity is experienced, a dehumidifier may be used to
help lower the water vapor content of the air.
3. Do not use an unvented room heater as the primary heat source
(an entire house).
Gas Inlet Pressure
Max
Minimum
10.5" W.C.
4.5" W.C.
13.0" W.C.
11.0" W.C.
10.5" W.C.
5.0" W.C.
13.0" W.C.
11.0" W.C.
10.5" W.C.
7.0" W.C.
13.0" W.C.
11.0" W.C.
10.5" W.C.
7.0" W.C.
13.0" W.C.
11.0" W.C.
BTU/hr.
Min. Rate
N/A
N/A
19,000
22,000
24,000
26,000
27,000
31,000
19,000
22,000
24,000
26,000
27,000
31,000
19,000
22,000
24,000
26,000
27,000
31,000