Dometic CoolFreeze CF-18 Operating Manual

Dometic CoolFreeze CF-18 Operating Manual

Dometic coolfreeze compressor cooler operating manual
Hide thumbs Also See for CoolFreeze CF-18:

Advertisement

_CF-18_60.book Seite 1 Donnerstag, 26. Juli 2007 3:18 15
CF-18
CF-18, CF-25, CF-35,
CF-40, CF-50, CF-60
EN
FR
ES
Form No.54-AA-MAD65A
Dometic Corporation
LaGrange IN 46761
CF-35
CF-25
7
26
48
4/08
THE SIGN OF COMFORT
CF-50
CF-40
Compressor Cooler
Instruction Manual
Glacière à compression
Manuel d'utilisation
Nevera por compresor
Instrucciones de uso
CF-60

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CoolFreeze CF-18 and is the answer not in the manual?

Questions and answers

Summary of Contents for Dometic CoolFreeze CF-18

  • Page 1 _CF-18_60.book Seite 1 Donnerstag, 26. Juli 2007 3:18 15 THE SIGN OF COMFORT CF-60 CF-50 CF-40 CF-35 CF-25 CF-18 CF-18, CF-25, CF-35, CF-40, CF-50, CF-60 Compressor Cooler Instruction Manual Glacière à compression Manuel d’utilisation Nevera por compresor Instrucciones de uso Form No.54-AA-MAD65A 4/08 Dometic Corporation LaGrange IN 46761...
  • Page 2: Notes On Using The Manual

    In this case, item 1 in figure 2 on page 3. Please observe the following safety instructions. Safety instructions Caution! DOMETIC International will not be held liable for claims for dama- ge resulting from the following: – Damage to the device resulting from mechanical influences and overvoltage –...
  • Page 3: General Safety

    _CF-18_60.book Seite 29 Donnerstag, 26. Juli 2007 3:18 15 Safety instructions General safety Caution – Danger of electrocution! When using the device on boats: If the device is powered by the mains, ensure that the power supply is protected with a ground fault interrupter circuit.
  • Page 4: Operating The Device Safely

    _CF-18_60.book Seite 30 Donnerstag, 26. Juli 2007 3:18 15 Safety instructions Operating the device safely Caution – Danger of electrocution! Do not touch exposed cables with your bare hands. This especially applies when operating the device from an AC mains. Before starting the device, ensure that the power supply line and the plug are dry.
  • Page 5: Scope Of Delivery

    _CF-18_60.book Seite 31 Donnerstag, 26. Juli 2007 3:18 15 Scope of delivery Scope of delivery Fig. 1, page 3, shows the scope of delivery. Item Quantity Description Cooler Connection cable for 12/24 V connection Only CF-35, CF-40, CF-50, CF-60 Connection cable for 120 V connection Only CF-35, CF-40, CF-50, CF-60 Carrying handle, consisting of:...
  • Page 6: Function Description

    _CF-18_60.book Seite 32 Donnerstag, 26. Juli 2007 3:18 15 Function description Function description The cooler can chill products, keep them cool as well as freeze them. A maintenance-free, CFC-free refrigerant circuit with compressor provides the cooling. The extra strong CFC-free insulation and powerful compressor ensure especially fast cooling.
  • Page 7: Operating And Display Elements

    _CF-18_60.book Seite 33 Donnerstag, 26. Juli 2007 3:18 15 Function description Operating and display elements CF-25, CF-35, CF-40 Lock for lid: Fig. 2 1, page 3 CF-18 Operating panel and connection socket (Fig. 3, page 3): Item Description Explanation TEMPERATURE Temperature controller, cooling temperature at the end positions: COLD: +10 °C (+50 °F)
  • Page 8 _CF-18_60.book Seite 34 Donnerstag, 26. Juli 2007 3:18 15 Function description CF-25, CF-35, CF-40, CF-50, CF-60 Operating panel (Fig. 4, page 4) Item Description Explanation Switches the cooler on or off when the button is pressed for between one and two seconds POWER Status indication...
  • Page 9: Operation

    _CF-18_60.book Seite 35 Donnerstag, 26. Juli 2007 3:18 15 Operation Accessories If you want to operate the coolers CF-18 and CF-25 from the 220–240 V AC mains, be sure to use the rectifier DOMETIC CoolPower EPS100. Operation Before initial use...
  • Page 10: Energy Saving Tips

    _CF-18_60.book Seite 36 Donnerstag, 26. Juli 2007 3:18 15 Operation Selecting the temperature units CF-25, CF-35, CF-40, CF-50, CF-60 You can switch the temperature display between Celsius and Fahr- enheit. This is how to do it: ® Switch on the cooler. ®...
  • Page 11: Connecting The Cooler

    _CF-18_60.book Seite 37 Donnerstag, 26. Juli 2007 3:18 15 Operation Connecting the cooler Connecting to a battery (Vehicle or boat) The cooler can be operated with 12 V or 24 V DC. Caution – Danger of damaging the device! Disconnect the cooler and other consumer units from the battery before you connect the battery to a quick charging device.
  • Page 12: Using The Battery Monitor

    (only CF-35, CF-40, CF-50, CF-60). CF-18, CF-25 To operate the coolers CF-18 and CF-25 from the 220–240 V AC mains, use the rectifier DOMETIC CoolPower EPS100 (accessory). Using the battery monitor The device is equipped with a multi-level battery monitor that protects your vehicle battery against excessive discharging when the device is connected to the on-board 12/24 V supply.
  • Page 13: Using The Cooler

    _CF-18_60.book Seite 39 Donnerstag, 26. Juli 2007 3:18 15 Operation This is how to select the battery monitor mode: CF-25, CF-35, CF-40, CF-50, CF-60 ® Switch on the cooler. ® Press the “SET” button (Fig. 4 4, page 4) three times. ®...
  • Page 14: Setting The Temperature

    _CF-18_60.book Seite 40 Donnerstag, 26. Juli 2007 3:18 15 Operation Caution – Danger from excessively low temperature! Ensure that the only those objects are placed in the cooler that are intended to be cooled at the selected temperature. CF-18 ® CF-18: Slide the sliding switch (Fig. 3 4, page 3) to HIGH if you wish to operate from a starter battery or to “LOW”...
  • Page 15: Switching Off The Cooler

    _CF-18_60.book Seite 41 Donnerstag, 26. Juli 2007 3:18 15 Operation CF-25, CF-35, CF-40, CF-50, CF-60 ® Press the “SET” button (Fig. 4 4, page 4) once. ® Use the “UP +” (Fig. 4 6, page 4) and “DOWN -” (Fig. 4 7, page 4) buttons to select the cooling temperature.
  • Page 16: Replacing The Device Fuse

    _CF-18_60.book Seite 42 Donnerstag, 26. Juli 2007 3:18 15 Operation Replacing the device fuse Only CF-35, CF-40, CF-50, CF-60 Caution – Danger of electrocution! Disconnect the connection cable before you replace the device fuse. ® Pull off the connection cable. ®...
  • Page 17: Replacing The Light Bulb

    _CF-18_60.book Seite 43 Donnerstag, 26. Juli 2007 3:18 15 Cleaning and maintenance 6.11 Replacing the light bulb Only CF-25, CF-35, CF-40, CF-50, CF-60 ® Press the switch pin (Fig. 0 2, page 5) downwards so that the transparent part (Fig. 0 1, page 5) of the lamp can be removed at the front.
  • Page 18: Troubleshooting

    Guarantee Our general guarantee conditions apply. If the product is defective, please send it back to the DOMETIC branch in your country (addresses on the back of the operating manual) or to your dealer. For repair and guarantee processing, please include the following...
  • Page 19: Technical Data

    _CF-18_60.book Seite 45 Donnerstag, 26. Juli 2007 3:18 15 Disposal Disposal ® Place the packaging material in the appropriate recycling waste bins wherever possible. If you wish to finally dispose of the device, ask your local recycling centre or specialist dealer for details about how to do this in accordance with the applicable disposal regulations.
  • Page 20 _CF-18_60.book Seite 46 Donnerstag, 26. Juli 2007 3:18 15 Technical data Test/certificates: – 73/23/EEC – Low Voltage Electrical Equipment Directive – 89/336/EEC – EMC Directive – 95/54/EEC Versions, technical modifications and delivery options reserved. This device is CFC-free. The coolant circuit contains R134a.

Table of Contents