Read the actual value of blanking top.
Command :
Command[0]
Command[1]
Data :
No data bytes.
Return data :
Data[0..1] = value of blanking top.
Data[0]
Data[1]
Example :
Read the actual value of blanking top of a projector with
address \x01. Suppose the blanking top equals 0.
Transmit
Start
Projector address
Command[0]
Command[1]
Checksum
Stop

blanking top, read

\x21
\x4c
msb of value
lsb of value
\xfe
\x01
\x21
\x4c
\x6e
\xff