ADA Mounting Requirements
1.
Keypads should be mounted so that the top of the number
touchpad is no more than 48 inches above the finished floor with
no obstructions in locations where wheelchair access is available
only from the front. Keypads can be placed higher if a wall mount
gooseneck allows closer access to the keypad.
Figure 2a
2.
Keypads should be mounted so that the
top of the number touchpad is no more
than 54 inches above the finished floor
with no obstructions in locations where
the wheelchair has sideways access.
3.
Keypads should be mounted so as not
to protrude more than 4 inches from
the wall. If mounted in a bollard or
pylon, it may protrude up to 12 inches.
Items mounted higher on the wall or
ceiling must be 80 inches or higher
above the finished floor.
4
Figure 2b
Figure 3
Figure 4