PTI security systems VP keypad controls entry Installation And Operation Manual page 23

Vp keypad access device
Table of Contents

Advertisement

Time Format
12 Hour
Max. #Attempts:00
(0-10,0=off):
Presence In Req.
Disabled
Card Format
26 Bit
Trip Relay NoCom
Disabled
Com Off Time:005
(1-25 sec):
Extended Codes
Disabled
Setup Complete
Press # key
Controls how the time is displayed. Options are 12
Hour and 24 Hour. The 12 Hour displays the time as
HH:MM:SS followed by am or pm. The hour will be
displayed as 12:00:00 am to 12:00:00 pm. The 24 Hour
format displays the time as HH:MM:SS without the am
or pm indicator. The hour will be displayed as 00:00:00
to 23:59:59. Factory default of 12 Hour.
Sets the maximum number of attempts within a one
minute period before the keypad will prevent further
code entry. If the number is set to three, then after three
successive attempts with invalid codes, the user will be
locked out. The lockout will remain active for 60 seconds
after the last key press. If the user keeps pressing keys
the lockout time will continue to be reset. The maximum
value is 10. The factory default is 000, which disables
the lockout feature.
Used where a vehicle sensor is installed in a drive
or other traffic area. When this feature is Enabled, a
presence needs to be detected (usually by a loop in the
ground under the driveway) before a code or card could
be used. This can also be used with an alternate alarm
system. Factory default is Disabled
Set the format of the cards being used for access.
Options available are 26, 30, 31, and 34. See the card
manufacturer specifications to determine the Bits of the
card. Factory default is 26 Bit.
After any code has been entered the display will read
Access Granted and the relay will be tripped to allow
access. When Enabled, the keypad will allow the relay
to be triggered when the communications are offline.
Enabling this setting compromises site security. Factory
default is Disabled.
Sets the amount of time the keypad should wait before
considering it has lost communication with the controller.
Any value from 1 to 25 seconds can be entered. Factory
default is 5 seconds.
Allows the keypad using a Wiegand device to use the
proximity card (26 bit format) and a 4-digit pin to access
the property when the function is Enabled. This function
provides higher security because the customer must use
the Wiegand device card and an access code. Factory
default is Disabled.
Message displayed when exiting from setup mode.
Pressing the # key will return the device to normal
operation. If no key is pressed, the device will return to
normal operation after a few seconds and all information
will be automatically saved.
19