ARISTOCRAT™ MODEL V36EC2 LOUVERED CIRCULATING ® WOOD-BURNING FIREBOX INSTALLATION INSTRUCTIONS SAVE THIS BOOK 17.22 This book is valuable. In addition to instructing you on how to install and maintain your appliance, it also contains information that will enable you to obtain 16.07 replacement parts or optional accessory items when needed.
STEP 4: When the firebox is installed upon a combustible floor a tions through completely. galvanized sheet ember protector (provided) must be installed be- These Vanguard components and firebox are safe when installed tween the firebox and the hearth extension as illustrated. according to this Installation Manual. Unless you use Vanguard...
Page 3
" FIREPLACE " COLLAR KEEP THIS AREA OPEN Maintain 3/4" air space between framing and fireplace. 4" " Figure 3 FRAMING DIMENSIONS AT 30° Figure 5 ASSEMBLING AND INSTALLING YOUR DOUBLEWALL CHIMNEY SYSTEM Each double wall chimney section consists of an outer pipe, flue pipe and one wire spacer.
Page 4
INSTRUCTIONS WHEN OFFSET OF CHIMNEY IS RISE AND OFFSETS NEEDED 48 36 18 12 36 18 12 12S TO INSTALL ELBOWS 1. To achieve desired offset, you may install combinations of 12", 18", 36", and 48", lengths of double wall pipe (see Rise and Off- sets chart and Figure 9 &...
THE STANDARD FOR UNVENTED ROOM HEATERS, ANS/IAS/ TERMINATION INSIDE SCREWS INNER PIPE OF CHIMNEY AGA Z21.11.2, ARE TO BE INSTALLED IN THIS FIREPLACE. CAULK NOTE: An appropriate Vanguard hood must be installed when COLLAR OVERLAP using an unvented gas log set. SHINGLES TOP AND SIDES FLASHING...
Figure 19 SIDE FRAMING BLOWER ASSEMBLY - VCBK3 A blower assembly is available for use with this firebox as an optional accessory. It is designed to be installed on Vanguard factory pre-wired FIREPLACE WIDE FRAMING SIDE FRAME Figure 17 firebox only. The optional blower assembly model VCBK3 can be installed prior to, or after installation of the firebox.
NOTE: Firebox must be wired to the house electrical system in MANTEL order for the blowers to operate. This blower system does not require A mantel may be installed if desired (see Figure 22) for minimum a wall switch. Refer to the VCBK3 blower assembly installation heights above and beyond opening of firebox face.
AIR KIT OPERATION NOTE: USE OF ANY OTHER GLASS DOOR ASSEMBLY NOT TESTED WITH THIS FIREPLACE MAY CONSTI- The damper rod for the air kit is located inside the face opening, TUTE A FIRE HAZARD AND WILL VOID THE DESA above the upper left top of the rear firebrick.