Installation (Continued)
AWarning
This hand dryer must have its own independent branch
circuit
using AWG #12 or #14 copper
wire.
The circuit should be equipped with a Ground Fault Interrupter and
a
120 Vac,
20
amp circuit breaker for
AWG #12 wire, or
a
120
Vac,
15
amp circuit breaker for AWG #14 wire.
Wire
it
to the terminal block. (No polarity)
l.Remove
s/ta"(15mm) of wire sheath from the
end.
2.Position the back panel on wall so that the
back electrical inlet can be connected to the
pre-installed electrical conduiVtubing with
lhe
Ye"
(16mm) connector.
3.For plaster or drywall construction,
position at least one side of the back panel
holes over the wooden studs for better
securement.
4.From the 7 possible hole locations on the
back panel, mark the 7 drill hole positions
on the
wall and remove the back
panel.
5.Drill the 7 holes and insert the 6 enclosed
self tapping screws (exclude the hole in the
lower right corner) through the back panel
and into the wooden studs.
To
secure the
opposite side of the back panel, use %"(M6)
Toggle Bolts (not included) due to the heavy
weight of the hand dryer. Do not use plastic
anchors as they may be insufficient to
support the weight.
6.For cement, brick or tile constiuction, use
#12 -'14 Anchors (not included).
T.Securely tighten the %"(16mm) connector
for grounding as shown in the drawing.
234"(7}mm)
Back Electrical
Inlel
in. (mm)
+
ol
Nr
(ou
6\
C\t
(\r
c\i
20%'
qi
R)
Tinhton
fn nnnnant
tho
back
panel
and electrical
conduit/tubing.
Run
the power cable through the hole
in
the
back
of
the unit, and pull
it
through the unit.
Power
cable
Green striped
bonding
wire
-Green
striped
bonding
wire
ble
-8-