CHAPTER 6. IPL (INITIAL PROGRAM LOADING) FUNCTION

The application program of the XE-A202 is written into the Flash ROM
in the CPU.
Since the CPU supplied as a service part does not include the applica-
tion program in it, the application program must be written when the
CPU is replaced with a new one.
To write the application program into the Flash ROM, connect the PC
and the XE-A202 with an RS-232C cable, and execute the PC software.
*Use a D-Sub 9pin cross cable employed in conventional communica-
tion between ECR-ECR (See APPENDIX: RS232C CABLE).
[Related parts/Tool]
PARTS NAME
VHI30624FGA-1
CPU (without application
program)
PosUtilityTool3
[IPL PROCEDURE]
1) Connect the XE-A202 and PC with an RS-232C cable.
<XE-A202 side>
2) Turn off the AC Power. (& remove batteries.)
3) Open the cabinet.
4) Change the IPL JUMPER PIN (SP1) to the rear side.
SP1
SP1
Default
When IPL
<Main PWB>
5) Close the cabinet.
6) Turn on the AC Power.
(At this time, ECR looks like inactive, but ECR waits the ROM data
from PC.)
LOCATION
PARTS CODE
No.
IC5
Software
XE-A202V IPL (Initial Program Loading) FUNCTION
<IPL software on PC>
7) Copy the following files in "PosUtilityTool3" into the hard disk of PC.
Postool3.exe
A202v.ROM
8) Boot "Postool3.exe."
9) Push [Add Files] in the screen.
10) Select the ROM DATA file. (File name: A202V.ROM)
11) By pushing [Send] in the screen, the ROM data is sent from PC to
ECR.
The address counter is shown on PC and counts up.
12) After about 3-minuites, the message "Complete" is shown on PC.
<After pushing "Add Files">
*1 COM Port is selectable between COM1 and 2.
*2 For "Send Type", select "Direct".
*3 Do not select "Extra Setting".
<XE-A202 side>
12) Turn on the AC Power.
13) Open the cabinet.
14) Change the Jumper PIN (SP1) to the front side. (default position)
15) Close the cabinet.
16) Turn on the AC Power.
Master Reset will be performed. If not, power off the XE-A202,
wait 1miniute and turn on the power again.
– 15 –