Caution To Be Used When Connecting The Rs-232 Cable; Appendix: Rs232C Cable; Chapter 7. Caution To Be Used When - Sharp XE-A202 Service Manual

Electronic cash register
Hide thumbs Also See for XE-A202:
Table of Contents

Advertisement

APPENDIX: RS232C CABLE

The RS-232C cable has the following internal connections:
(Equivalent to a cross cable used in the conventional connection of
ECR-ECR)
9PIN D-SUB
SD
3
2
RD
RTS
7
DCD
1
DTR
4
DSR
6
CTS
8
SG
5
SD
: TRANSMITTED DATA
RD
: RECEIVED DATA
DTR : DATA TERMINAL READY
DSR : DATA SET READY
RTS : REQUEST TO SEND
DCD : DATA CARRIER DETECTOR
CTS : CLEAR TO SEND
CHAPTER 7. CAUTION TO BE USED
When connecting the RS-232 cable to the XE-A212, be sure to observe
the following condiiton:
9PIN D-SUB
Secure the attached core (RCORF6699BHZZ) to the RS-232
3
SD
cable in the area within 20mm from the connector.
[This is a necessary procedure to support the EMI (Electronics
Magnetic Interface).]
2
RD
7
RTS
1
DCD
4
DTR
6
DSR
8
CTS
5
SG
XE-A202V CAUTION TO BE USED WHEN CONNECTING THE RS-232 CABLE
– 16 –
WHEN CONNECTING
THE RS-232 CABLE
RS232 CONNECTOR
Within
20mm
Secure the core
(RCORF6699BHZZ)
to the cable in the area
within 20 mm from the
connector with a lock
band.

Advertisement