Speci Cations - Winchester WG SERIES Installation Instructions Manual

Wg series sealed combustion downflow gas furnace sizes: 60, 70, 77, 90
Table of Contents

Advertisement

Winchester Gas Furnace
80 AFUE - AUTOMATIC HOT SURFACE IGNITION
Model No.
WGSH-6000
Input, BTUH
60,000
Output, BTUH
48,000
AFUE, %
80
With A-Coil Cabinet
YES
Ignition Type
Auto-Elect
Air Temperature Rise, Range - F
40-70
Designed Max Outlet Air Temp-F
170
Natural Gas Orifice Size
27
Propane (LP) Gas Orifice Size
44
Blower-Heat or Heat/Cool
Max. External SP (Duct), In. W.C.
Fuel
High Alitiude
Furnace Flue Pipe
Gas Connection
Electric Service
Fuse or Circuit Breaker
Thermostat Circuit
Filters
PRODUCT CODE
W
G
Winchester Gas
ACCESSORIES
PART NO.
DESCRIPTION
90-RJF1729-AL Body, Roof Jack, Gas-FLAT
90-RJF2551-AL Body, Roof Jack, Gas-FLAT
90-RJS1729-AL Body, Roof Jack, Gas-SLOPE 3/12
90-RJS2551-AL Body, Roof Jack, Gas-SLOPE 3/12
90-RJS3868-AL Body, Roof Jack, Gas-SLOPE 3/12
90-RJS6399-AL Body, Roof Jack, Gas-SLOPE 3/12
90-RJCRWN-AL Crown, Roof Jack, Gas
90-TRN-RNG
Ceiling Trim Ring, Roof Jack
RJTRC
Kit, Transit - Roof Jack -- Cap & Label
90-OUTXT16-AL Roof Jack Outdoor Extension - Gas 16"
90-INXST10-AL Roof Jack Indoor Extension - Gas 10"
90-RJS56
5-6/ 12 Slope, Roof Saddle Adapter
90-DCU0-01
86AA0013 Duct Conn + 87FB0005 Flr Base
90-DCU0-02
86AA0014 Duct Conn + 87FB0005 Flr Base
90-DCU0-03
86AA0015 Duct Conn + 87FB0005 Flr Base
90-CABEXT4
White, Top, Cabinet Extender Plate
Winchester by Mortex Products Inc. / Fort Worth, TX 76106
WGSH-7000
WGSH-7700
WGSH-9000
70,000
77,000
90,000
56,000
61,600
72,000
80
80
80
YES
YES
YES
Auto-Elect
Auto-Elect
Auto-elect
40-70
40-70
45-75
170
170
175
22
19
17
42
41
37
10 X 8, 1/4 HP, 2 SPD
For elevations above 2,000 feet, reduce input 4% for each 1,000 ft. elevation above sea level
F
F = Furnace
H = Heating Only
S = Short
WGSH-6042
WGSH-7042
WGFD-7742
60,000
70,000
77,000
48,000
56,000
61,600
80
80
80
YES
YES
YES
Auto-Elect
Auto-Elect
Auto-Elect
40-70
40-70
40-70
170
170
170
27
22
19
44
42
41
10 X 8, 1/3 HP, 3 SPD
0.3
Natural Gas (Factory Equipped) - LP Orifice Furnished
Must Use RJS Roof Jack for Sloped Roof or RJF Roof Jack for Flat Roof
1/2" FPT
115 VAC, 60 Hz, 1 PH
15 Amp
24 VAC, 60 Hz, 40VA
2 - 16" X 20" X 1"
D
D - Downflow
NOTES
Height 94 1/2 X 106 1/2
Height 102 1/2 X 128 1/2
Height 94 1/2 X 106 1/2
Height 102 1/2 X 128 1/2
Height 115 1/2 X 145 1/2
Height 140 1/2 X 176 1/2
Use w/ Gas Roof Jack Body
Trim out to inside RJ - Pipe
For transport-Remove on site
Extend pipes / crown - 16 in.
Extend pipes / crown - 10 in.
Add to RJS 3/12 Roof Jack
Floor to Duck 1 in. - 4 in.
Floor to Duck 6 in. - 8 in. STD
Floor to Duck 8 in. - 12 in.
Fill alcove 76" top opening
Installation Instructions
WGFD-9042
WGSH-6060
WGSH-7060
90,000
60,000
70,000
72,000
48,000
56,000
80
80
80
YES
YES
YES
Auto-elect
Auto-Elect
Auto-Elect
45-75
40-70
40-70
175
170
170
17
27
22
37
44
42
10 X 8, 3/4 HP, 4 SPD
60
-
Up To Number of
Heating
Tons of Cooling
Input
WG Installation Instructions
WGFD-7760
WGFD-9060
77,000
90,000
61,600
72,000
80
80
YES
YES
Auto-Elect
Auto-elect
40-70
45-75
170
175
19
17
41
37
42
2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents