Blower Performance Chart - Winchester WG SERIES Installation Instructions Manual

Wg series sealed combustion downflow gas furnace sizes: 60, 70, 77, 90
Table of Contents

Advertisement

Winchester Gas Furnace
WG BLOWER PERFORMANCE CHART
H2/10 OR (00) BLOWER - 10 X 8 WHEEL 1/4 HP 2 SPD MOTOR
CFM-NO-COIL
CFM-WITH-COIL
A3/12 OR (42) BLOWER - 10 X 8 WHEEL 1/3 HP 3 SPD MOTOR
(Accessory PN 87-1008-312A1)
CFM-NO-COIL
CFM-WITH-COIL
A4/16 OR (60) BLOWER - 10 X 8 WHEEL 3/4 HP 4 SPD MOTOR
(Accessory PN 87-1008-316A1)
CFM-NO-COIL
CFM-WITH-COIL
Winchester by Mortex Products Inc. / Fort Worth, TX 76106
Installation Instructions
ESP INCHES WC DUCT
SPD TAP
0.1
0.2
0.3
LO
940
885
835
HI
1225
1165
1110
LO
865
825
775
HI
1105
1050
1010
LO
980
950
910
MED
1220
1170
1120
HI
1460
1400
1340
LO
945
905
865
MED
1130
1085
1030
HI
1300
1240
1180
LO
995
960
915
MED
1205
1165
1130
MED-HI
1470
1425
1385
HI
1810
1765
1720
LO
950
905
885
MED
1145
1115
1080
MED-HI
1375
1345
1315
HI
1700
1660
1620
WG Installation Instructions
0.4
0.5
780
725
1030
970
730
670
930
870
875
825
1065
1015
1270
1195
815
775
970
905
1105
1085
875
825
1090
1045
1345
1310
1680
1635
835
790
1035
1000
1280
1245
1575
1540
13