Gardsman CTC-1132 Installation & Operating Manual page 42

Table of Contents

Advertisement

<
N
O
T
E
>
<
N
O
T
E
>
Please refer to section. check other
fault.
3.12.1. Fault Message Display
When any fault situation persists, the
Control Panel will respond as below when
it is in Disarmed mode:
The Yellow LED will light to indicated
the fault condition
The LCD will display the type of fault
and the source of the fault in the
Fault Display section of the User
Menu.
A warning beep will sound at every
30 seconds.
If a fault condition is detected while the
system is in full arm mode, the fault event
display will not be generated until the
system is disarmed.
3.12.2. Clearing Fault Message Display
The Yellow LED will turn off automatically
once all of faulty conditions are restored, or
any faulty devices are removed. It cannot
be cleared manually.
On the contrary, the fault message display
retains even if the faulty conditions have
been restored.
The fault message can only be cleared
manually after the fault condition has been
rectified.
3.12.3. Viewing/Clearing the Fault
Message
To check what the fault condition is,
Step 1. When the system is in Disarmed mode.
Enter your PIN Code followed by OK.
Step 2. The screen will display
F a u l t
A r m
and the cursor stays at Fault Dsp
Step 3. Press OK key to select Fault Dsp
D s p
Step 4. All the fault events are listed. Use
&
keys to move the cursor
downwards or upwards. The screen
is also scrolled down or up
respectively.
Step 5. After viewing all the fault events, press
key, a prompt message is displayed.
C l e a r
Step 6. After the fault condition has been
rectified, press OK key and the fault
event will be cleared and the screen
returns to Alarm off.
<
<
N
N
O
O
T
T
E
E
>
>
In Step 6, if
screen returns to Alarm off, and the
Yellow LED stays on, the Control
Panel keeps sounding a short beep
every 30 seconds, and the fault event
display retains.
If the fault condition has not been
rectified, the fault event display will not
be cleared.
while you try to arm the system and
the faulty condition inhibits the system
from being armed, the fault message
will be displayed again. The fault
event display can be cleared only after
the fault condition has been rectified.
Even when the fault messgae is
cleared, the fault event will still
retained in the Log.
3.12.4. Fault Event Response
When a fault condition is detected, in
addition to the fault display, the Control
Panel
will
according to the nature of the fault event.
In all modes, the Control Panel and the
external sirens will NOT sound audible
siren for fault event (except Sabotaged
alarm).
In all modes, when Panel AC power failure
or tamper trigger happens, the Control
Panel will send fault report by SMS.
However, for all other fault events, the
Control Panel will NOT send fault report by
SMS.
37
F a u l t
D s p :
( O K ? )
key is pressed, the
It will come on again
also
respond
separately

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents