07
Water flow servo present recognising positioning
*Note 3 Water Flow Servo Positioning
Servo Position
08
Inlet water temperature
(PCB recognition value)
(Example 25 = 25°C)
09
Hot water fan current flow value
(Example 6 x 10 = 60 mA)
10
Bath fill amount (this counts the litres during bath
fill operation).
To return to normal operation
Press the ON/OFF button again while holding down the Water Temperature "DOWN" (Cooler)
button.
Error History
To Display Error Memory (History)
(This feature will show the last 10 faults in sequence)
1.
Turn off at the ON/OFF button. (This can be done during
operation)
2.
Press the ON/OFF button while holding the Water Temperature
"UP" (Hotter) button.
The Sequence will be shown in the Water Temperature display.
Error Code will be shown in the Clock display. (See service
Manual for error codes).
Where there are less than a total of 9 errors, "FFF" or " - - " will
be displayed in the Clock display.
To return to normal operation.
Press the ON/OFF button again while holding the Water Temperature "UP" (Hotter) button.
This feature will automatically shut down after 3 minutes.
Service Manual Infinity 16e and 20e
Service Manual Infinity 16e and 20e
REU-V1616W/REU-V2018W/REU-V2020W
Open
Display
"1"
None
Centre
"0"
°C
10 mA
Litres
- 32 -
0~2 *Note 3
Closed
"2"
0~999
0~999
0~999
Issue 1 - 10/10/03 ©Rinnai