Water Filters
If connecting to water filtration, filter only the
water to the reservoir, not to the condenser.
Install a new cartridge if the filters were used with
a prior machine.
All models require drain tubing to be attached to
them. Air cooled models have a single 21mm
O.D. male drain fitting in the back of the cabinet.
Water cooled models have the same fitting plus
an additional 3/4" male drain fitting in the back of
the cabinet.
Note: This NSF listed model has a 1" anti-
back flow air gap between the water inlet
tube end and the highest possible reservoir
water level, no back flow device is required
for the potable water inlet.
Drain Tubing:
Use rigid drain tube supplied with machine and
route them separately - do not Tee into the bin's drain.
Horizontal runs of drain tubing need a 1/4" fall per
foot of run for proper draining.
Follow all applicable codes.
Electrical
See the spec sheet or User's Manual for Wire
Size and Maximum Fuse Size ratings.
The machine is supplied with a 1,5 meter length
power cord.
Install the electrical plug accordingly to the local
standard needed.
The dataplate on the back of the cabinet details
the power requirements, including voltage,
phase, minimum circuit ampacity and maximum
fuse size. Extension cords are not permitted. Use
of a licensed electrician is recommended.
Follow all applicable local, state and national
codes.