Westgate DV48 Owner's Manual

Westgate vented gas fireplace heater owner's manual
Hide thumbs Also See for DV48:

Advertisement

SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER.
PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
INSTALLER:
Leave this manual with the appliance.
CONSUMER:
Retain this manual for future reference.
WHAT TO DO IF YOU SMELL GAS
• Open windows/extinguish any open
fl ame.
• Do not try to light any appliance.
• Do not touch any electrical switch
or use any phone in your building.
• Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
• If you cannot reach your gas
supplier, call the fi re department.
FOR YOUR SAFETY: Do not store or use gasoline or
other fl ammable vapours and liquids in the vicinity of
this or any other appliance.
WARNING:
If the information in this manual is
not followed exactly, a fi re or explosion may result
causing property damage, personal injury or loss of
life. Installation and service must be performed by a
qualifi ed installer, service agency or the gas supplier.
Massachusetts installations (Warning): This product must be installed by a licensed plumber or
gas fi tter when installed within the Commonwealth of Massachusetts. Other Massachusetts code
requirements: Flexible connector must not be longer than 36in., a shut off valve must be installed;
only direct vent sealed combustion products are approved for bedrooms/bathrooms. A carbon
monoxide detector is required in all rooms containing gas fi red direct vent appliances. The fi replace
damper must be removed or welded in the open position prior to installation of a fi replace insert.
DV48
B Y : S H E R W O O D I N D U S T R I E S L T D
B Y : S H E R W O O D I N D U S T R I E S L T D
OWNER'S
MANUAL
This appliance may be installed in an
after-market permanently located,
manufactured (mobile) home,
where not prohibited by local codes.
This appliance is only for use with
the type of gas indicated on the
rating plate. This appliance is not
convertible for use with other gases,
unless a certifi ed kit is used.
50-2003

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DV48 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Westgate DV48

  • Page 1 SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER. PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE DV48 B Y : S H E R W O O D I N D U S T R I E S L T D B Y : S H E R W O O D I N D U S T R I E S L T D OWNER’S...
  • Page 2: Safety Precautions

    AFETY RECAUTIONS FOR SAFE INSTALLATION AND OPERATION OF YOUR “WESTGATE” HEATER, PLEASE CAREFULLY READ THE FOLLOWING INFORMATION: • All Westgate gas-fi red appliances must be • To prevent injury, if the pilot or pilot and installed in accordance with their instructions.
  • Page 3: Table Of Contents

    ABLE OF ONTENTS Safety Precautions..................2 Table of Contents....................3 Codes And Approvals..................4 Specifi cations....................5 Dimensions..................5 Rating Label ..................6 Door Removal and Installation..............7 Installation Set-Up...................7 Firebox Liner Installation...............7 Log Burner / Ember Bed Installation............9 Log Set Installation................10 Glass Burner Installation..............12 Porcelain Panel Kit Installation............14 Optional Front Installation..............16 Start-Up &...
  • Page 4: Codes And Approvals

    After the unit has gone through the fi rst burn, turn the unit off including the pilot, let the unit get cold then remove the glass door and clean it with a good gas fi replace glass cleaner, available at your local WESTGATE dealer.
  • Page 5: Dimensions

    PECIFICATIONS IMENSIONS 4” (101mm) 20” (508mm) Figure 1. Dimensions of the Firebox. ATING ABEL OCATION The Rating and Lighting instruction label is located below the door frame, underneath the fi rebox attached to a chain. To access the label, slide the plate forward out from under the fi rebox. Always return it when fi...
  • Page 6: Specifi Cations

    PECIFICATIONS ATING ABEL DO NOT REMOVE THIS LABEL / N'ENLEVEZ PAS CETTE ETIQUETTE DV48 VENTED GAS FIREPLACE HEATER ENVIRO MODEL: DV48 FOYER AU GAZ A EVACUATION MODELE ENVIRO: Certifi ed for use in Canada & USA WH# 16354 NAT: (Gaz naturel) LPG (Propane) Certifi...
  • Page 7: Door Removal And Installation

    NSTALLATION EMOVAL AND NSTALLATION 1) The fi replace door is hung on two (2) hooks on the top of the fi rebox. The two (2) door latches at the bottom of the fi rebox hook over the tabs on the bottom of the door frame. 2) Lower the door latch tool underneath the door frame.
  • Page 8 NSTALLATION 1. Prior to installing the fi rebox liners, you will need to ensure the Rear Brick Panel Support is in the correct position. The support is located at the back of the fi rebox (see Figure 9) and can be installed in two (2) positions.
  • Page 9: Log Burner / Ember Bed Installation

    NSTALLATION URNER MBER NSTALLATION 1. Use the two (2) T-20 screws provided; install the rear burner shield onto the back of the burner. The mounting holes are just above the mixing tubes at the rear of the burner, refer to Figure 15. Figure 16: Burner Mounting Brackets.
  • Page 10: Log Set Installation

    NSTALLATION Figure 20: Slot for Firebox Grate. Figure 21: Tab on Firebox Grate. 4. Install the burner accent pieces as shown in Figure 19. There are a left, a right and a front ceramic trim. On each side of the burner and on the inside of each burner side accent pieces there is a slot, which should be aligned in order to position the log grate correctly (see Figure...
  • Page 11 NSTALLATION Figure 25: Log 3 in Place. Figure 26: Log 4 in Place. 2. Install Left Rear log with the right side on the grate, using a groove on the bottom of the log to index itself to the grate (see Figure 24). The right side self locates on the fi...
  • Page 12: Glass Burner Installation

    NSTALLATION Figure 30: Log 8 in Place. Figure 31: Log 9 in Place. 8. Situate Log 8 between the right grate fi nger, the right fi rebox liner and the grate cross bar (see Figure 30). On the back of the log near the top end is a ceramic pin, this pin sits into a groove on the top of Log 9.
  • Page 13 fl ow to this location. Ensure the glass tray hole is properly positioned over the port in the burner. 5. The DV48 glass burner option is supplied with two (2) quantities of glass, black and white. There is enough of either to fi ll the burner, so you can decide whether to install all white, all black, or some type of mixture (example in Figure 37).
  • Page 14: Porcelain Panel Kit Installation

    43). 7. If the optional rock accent kit was purchased for the DV48, you can place the rocks in a random pattern around the glass tray. A few can straddle the ⅜” (8mm) gap around the glass tray. Try to keep them looking randomly placed.
  • Page 15 NSTALLATION Figure 46: Rear & Left Porcelain Panels in Place. Figure 47: Top Porcelain Panel in Place. 4. Install the Left Firebox Liner Panel; it sits on the bottom front edge of the fi rebox (see Figure 46), a support bracket at the lower rear of the fi...
  • Page 16: Optional Front Installation

    NSTALLATION 8. Place one of the Permanent Magnets provided on the front edge of the Burner Cover Supports as shown in Figure 49. 9. Install the Burner Assembly; refer to Step 1 & 2 of G LASS URNER NSTALLATION 10. Place the Ceramic Burner Front on top of the Burner Cover Supports as shown in Figure 49. This part should be pulled forward until it contacts the metal brackets in the front.
  • Page 17 NSTALLATION Install the front by lifting it parallel to the fi replace with the mounting bracket hooks pointing towards the fi replace. Slide the hooks all the way into the slots between the Glass Door Frame and the drywall fl anges of the fi replace. Pull down on each corner to make sure the hook is engaged with the hanger.
  • Page 18: Start-Up & Operation

    PERATIONS The Profl ame GTMF is a modular remote control system that directs the functions of the DV48. The Profl ame GTMF is confi gured to control the on/off main burner operation, its fl ame levels and provides on/off and Smart thermostatic control of the appliance.
  • Page 19 & O TART PERATION TRANSMITTER (Remote Control with LCD Display) The Profl ame Transmitter uses a streamline design with a simple button layout and informative LCD display (Figure 55). The Transmitter is powered by three (3) AAA type batteries. A Mode Key is provided to Index between the features and a Thermostat Key is used to turn on/off or index through Thermostat functions (Figure 55 &...
  • Page 20: Wall Mounting The Receiver

    & O TART PERATION OUNTING ECEIVER The receiver can be placed inside a standard Junction type wall box either by itself or in combination with a light dimmer control. This installation can take place up to 8’ft (2.4m) from the appliance control valve. 1.
  • Page 21 Remote Actuated Accent Lights The DV48 is shipped with two (2) fi rebox accent lights. They are connected to the auxiliary power outlet of the Profl ame Fan Control Module. The lights can be turned on or off using the Auxiliary function on your remote control.
  • Page 22 Split Valve Operation The split fl ow operation on the DV48 turns off the rear section of the burner, greatly reducing the heat output of the unit. If you’d like to have the fi replace on but would not like to have as much heat in the room, you can turn off this function.
  • Page 23: Air Shutter Adjustment

    Turn off the appliance if it is not going to be attended for any length of time. Always place the Transmitter where children cannot reach it. HUTTER DJUSTMENT The DV48 is setup to work with two (2) gas orifi ces. The orifi ce on the left (looking...
  • Page 24: Check For Proper Burner Flame

    LAME Once your new DV48 has run through the “fi rst fi re”, (see section on fi rst fi ring) check for proper fl ame appearance. A gas appliance’s performance is dependent on several factors. Vent confi guration, fuel type, altitude and restrictor setting are all factors in how the fi...
  • Page 25: Service / Maintenance

    ⁄ M ERVICE AINTENANCE IGHTING NSTRUCTION ABEL Hot while operating. Do not touch. Severe burns may result. Keep CAUTION: children, clothing, furniture, gasoline or other flammable vapors away. CAUTION: Do not operate this fireplace with the glass removed, cracked or broken. Replacement of the panel(s) should be done by a licensed or qualified person! This appliance needs fresh air for safe operation and must be installed with provisions for combustion and ventilation air.
  • Page 26: Light Bulb Replacement

    NNUAL ERVICE The DV48 will require maintenance, which can usually be planned on an annual basis. Service should include cleaning, battery replacement, light replacement, venting inspection and inspection of the burner, log sets and fi rebox liners.The vemting systems should be periodically examined by a qualifi ed agency.
  • Page 28: Installation Data Sheet

    NATURAL GAS (NAT) PROPANE(LPG) _________________________________________ INLET GAS PRESSURE:_________in wc _________________________________________ MAIN BURNER ORIFICE:__________# DMS PHONE:___________________________________ PILOT ORIFICE #_________OR________in diam. INSTALLER’S SIGNATURE: _________________________________________ MANUFACTURED BY: SHERWOOD INDUSTRIES LTD. 6782 OLDFIELD RD. SAANICHTON, BC, CANADA V8M 2A3 February 15, 2012 www.westgatefi replaces.com C-13875...