Operation (Procon Ii One-Scene) - Teatronics Lighting Controls PROCON II Owner's Manual

Lighting control console
Table of Contents

Advertisement

T E AT R O N I C S L I G H T I N G C O N T R O L S , I N C .
T E AT R O N I C S L I G H T I N G C O N T R O L S ,
Teatronics Lighting Controls, Inc. one-scene consoles are designed to be used with the Warrior
and the GLX line of dimmer packs.
Each channel has a mode selector switch "1" and a calibrated linear control "2". In the up, or
"A" position, the A Submaster will proportionally adjust the output of that channel (and all
other channels set to "A"). In the down, or "B" position, that channel will be proportionally
controlled by the B Submaster (along with all others set to "B").
The BLACKOUT switch "3" is located above the Grand Master. Operating this switch downward
causes an immediate cutoff of the output of all dimmers on the console. Turning the switch back
on without changing the dimmer settings will cause all channels to "switch on" to the setting
indicated.
A green LED "4" directly above the submaster, controls indicates that the console is on and
receiving power. A Grand Master control "5" is provided for total control console proportioning.
BUMP BUTTONS "6" cause the output of the respective channels to go to "full" when depressed
by the operator. These BUMP (or flash) buttons override all channel and submaster controls. In
addition to one per channel, each A or B has a bump button as well, allowing a group of dimmers
to be flashed.
5
PROCON II
Lighting Control Console
OPERATION
(Procon II One-Scene)
4
3
1
2
6
I N C .
12/01/94
Page//
4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents