2. S VIDEO, VIDEO OUT Adjustment
2-1. Preparations
Perform the following data setting before the "S VIDEO,
VIDEO OUT Adjustment".
Switch setting
1) DISPLAY OUTPUT switch ............................................ OFF
Order Page
Address Data
1
0
2
0
8
3
(18)
8
4
(18)
C
5
(1C)
8
6
(18)
8
7
(18)
8
0
9
10
0
11
B
12
C
13
B
14
0
HVR-M15J/M15U/M15N/M15E/M15P/M15C
Procedure
01
01
10
01
00
01
Press PAUSE (Write) button.
01
60
Press PAUSE (Write) button.
0F
10
Press PAUSE (Write) button.
06
55
Press PAUSE (Write) button.
04
C0
Press PAUSE (Write) button.
10
00
Wait for 5 sec.
FF
3E
00
02
85
Check the data is "55".
00
00
FF
00
2-2. S VIDEO OUT Y Level Adjustment (VD-036 board)
Mode
Signal
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified value
Adjusting method:
Order Page Address Data
1
2
3
4
5
C
8A
6
C
8A
7
8
9
10
C
90
11
C
90
12
6-47
E-E
No signal
Y signal terminal of S VIDEO OUT
jack (75 Ω terminated)
Oscilloscope
C
8A (NTSC)
90 (PAL)
A = 1000 ± 14 mVp-p
Procedure
Perform "Preparations".
Set the HOLD switch of
adjustment remote com-
mander to "OFF" (NORMAL
position).
Set the 60i/50i SEL (OTH-
ERS menu) to "60i".
Set the HOLD switch of
adjustment remote com-
mander to "HOLD" (SER-
VICE position).
Change the data and set the Y
signal level (A) to the NTSC
specified value.
Press PAUSE (Write) button.
Set the HOLD switch of
adjustment remote com-
mander to "OFF" (NORMAL
position).
Set the 60i/50i SEL (OTH-
ERS menu) to "50i".
Set the HOLD switch of
adjustment remote com-
mander to "HOLD" (SER-
VICE position).
Change the data and set the Y
signal level (A) to the PAL
specified value.
Press PAUSE (Write) button.
Perform "Processing after
Complete Adjustment".
H
Fig. 6-2-3
A