Power and Protection Indicators

Assistance
The power and protection indicator includes a dual color
green and red light, and an alarm.
Green Light
Installation
Power on – The green light should remain on steady.
Secondary Icons
Red Light and/or Alarm
Current overload – The red light will turn on momentarily,
then the inverter will shutdown. The inverter will continue
to check for appropriate current levels while trying to
Notice
restart the load.
DC input voltage overload – The red light will turn on and
the inverter will shutdown. The inverter will continue to
check for appropriate voltage levels while trying to restart
the load.
DC input voltage shortage – As a warning that the voltage
is getting low, the internal alarm will sound. When the
voltage is too low, the inverter will shutdown and the red
ntro
Operation
light will turn on. The inverter will continue to check for
Customer
Warranty
Assistance
appropriate voltage levels while trying to restart the load.
Temperature overload – The red light will blink, then the
inverter will shutdown. The inverter will continue to check
Installation
for appropriate temperature levels while trying to restart
Notes
the load.
Icons
NOTE A momentary sound of the internal alarm
and/or flash of the red light is normal at start up.
Notice
Caution
12
Warranty
Notes
Caution
Warning
Warning
Operation
Intro
Operation

Operating Limits

Power Output
The inverter can deliver 800 watts for about 60 minutes.
The inverter must cool for 15 minutes before it can
Installation
resume operation at 800 watts. Note: The wattage
rating applies to resistive loads.
Secondary Icons
The inverter will operate most AC loads within its power
rating. Some induction motors used in freezers, pumps,
and other motor-operated equipment require very high
surge currents to start. The inverter may not be able
Notice
to start some of these motors even though their rated
current draw is within the inverter's limits. The inverter
will normally start single phase induction motors rated
at one-half HP or less.
Input Voltage
The inverter will operate from input voltage ranging
from 10 volts to 15 volts. Optimum performance will occur
when the voltage is between 12 volts and 14 volts. If the
voltage drops below 10.5V+/-0.3V, an audible
low battery warning will sound. The inverter will shut
down if the input voltage drops below 9.5V+/-0.3V. This
protects the battery from being over-discharged. It will
restart when the input voltage exceeds 12V+/-0.3V.
The inverter will also shut down if the input voltage
exceeds 15.75V+/-0.75V. This protects the inverter
against excessive input voltage. Although the inverter
has protection against over-voltage, it may still be
damaged if the input voltage were to exceed 16 volts.
Operating Limits