5.5.

Compressor Rotational Speed Control

1. When power is turned on, rotational speed is fixed 42 (r/s) for 10 minutes.
2. The use rotational speed.
Compressor rotational speed decided by the ATC temperature.
• Each ATC temperature condition, for the first step, it starts the lowest rotational speed of available range.
• If the temperature difference is big between PCC and FCC, the rotational speed changes one rank up.
5.6.

Compressor Starting Control

The compressor is not start while waiting timer is operating.
And when power is turned on, compressor starting control is not available.
5.7.

Compressor Fan Control (for cool down the Compressor)

Acording to the compressor rotational speed, compressor rotation speed controlled under the below.
ATC temperature
25 r/s
22°C below
O
23 ~ 28°C
O
29 ~ 32°C
33°C above
After power turning on
After FC Defrost stopping (Improvement of start after defrost)
After compressor stopping (Prevention of trip when re-starting)
Inverter protection
Compressor rotational speed
33 r/s
42 r/s
52 r/s
O
O
O
O
O
O
O
O
O
O
O
20
67 r/s
75 r/s
O
O
O
O
O
0 minute
10 minutes
10 minutes
10 minutes

Advertisement